Red Lion 97081001

Red Lion RL-SWJ100 1 HP Shallow Well Jet Pump Instruction Manual

மாடல்: 97081001

1. அறிமுகம்

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-SWJ100 1 HP Cast Iron Shallow Well Jet Pump. Please read these instructions thoroughly before attempting to install or operate the pump. Retain this manual for future reference.

Red Lion RL-SWJ100 1 HP Shallow Well Jet Pump, red cast iron body with black motor housing.
Figure 1: Red Lion RL-SWJ100 1 HP Shallow Well Jet Pump

2. பாதுகாப்பு தகவல்

WARNING: Risk of severe injury or death by electrical shock, or damage to the system.

  • பம்பைத் தொடும் முன் எப்போதும் மின் இணைப்பைத் துண்டிக்கவும்.
  • A Ground Fault Circuit Interrupter (GFCI) is required for electrical connections.
  • மின்கம்பி சேதமடைந்தால், அதை தகுதியான பணியாளர்கள் மட்டுமே மாற்ற வேண்டும்.
  • Installation and servicing of this equipment should be performed by technically qualified personnel familiar with the correct selection and use of appropriate tools, equipment, and procedures.
  • இந்த தயாரிப்பு உங்களை ஈயம் உள்ளிட்ட ரசாயனங்களுக்கு ஆளாக்கக்கூடும், இது கலிபோர்னியா மாநிலத்திற்கு புற்றுநோய் மற்றும் பிறப்பு குறைபாடுகள் அல்லது பிற இனப்பெருக்க தீங்குகளை ஏற்படுத்தும் என்று அறியப்படுகிறது. மேலும் தகவலுக்கு செல்க www.P65Warnings.ca.gov.
A person wearing blue work clothes and gloves is handling electrical wires, emphasizing the need for electrical experience.
Figure 2: Electrical experience is required for installation.

3. தயாரிப்பு முடிந்துவிட்டதுview

The Red Lion RL-SWJ100 is a 1 HP cast iron shallow well jet pump designed for providing fresh water to rural homes, farms, and cottages. It is suitable for suction lifts down to 25 feet. The pump includes a 30/50 pressure switch and is self-priming after initial prime.

முக்கிய அம்சங்கள்:

  • Shallow Well Application: Designed for wells less than 25 feet deep.
  • இரட்டை தொகுதிtage Motor: Heavy-duty 115/230 Volt motor, factory-set for 230 Volts, easily switchable to 115 Volts.
  • நீடித்த கட்டுமானம்: Heavy-duty cast iron casing for longevity. Impeller and volute are made of glass-filled thermoplastic.
  • Integrated Pressure Switch: Includes a 30/50 pressure switch with auto shut-off.
  • இணைப்புகள்: 1-1/4-inch Female NPT threaded intake; 1-inch Female NPT threaded discharge.
Diagram showing the internal components and features of the Red Lion RL-SWJ series shallow well jet pump, including motor terminal box, adjustable pressure switch, 1 inch FNPT discharge, 1-1/4 inch FNPT intake, cast iron casing, glass-filled thermoplastic impeller and diffuser, and integrated venturi/nozzle assembly.
Figure 3: RL-SWJ Series Features Diagram

4. விவரக்குறிப்புகள்

பண்புமதிப்பு
மாதிரி எண்97081001
குதிரைத்திறன் (HP)1 ஹெச்பி
தொகுதிtage115/230 Volts (Dual Voltage)
Ampஎரிச்சல்13.2 Amps @ 115V; 6.6 Amps @ 230V
வாட்tage4800 வாட்ஸ்
அதிகபட்ச ஓட்ட விகிதம்நிமிடத்திற்கு 17 கேலன்கள் (GPM)
அதிகபட்ச அழுத்தம்74 பி.எஸ்.ஐ
Suction/Intake1-1/4-inch Female NPT
வெளியேற்றம்1-inch Female NPT
பொருள்Cast Iron (body), Glass-filled thermoplastic (impeller/volute)
தயாரிப்பு பரிமாணங்கள் (L x W x H)14"லி x 9"அங்குலம் x 9.5"அங்குலம்
பொருளின் எடை28.5 பவுண்டுகள்
உள்ளிட்ட கூறுகள்30/50 Pressure Switch, Instruction Manual, Pump
Performance chart for Red Lion RL-SWJ100 shallow well jet pump, showing total dynamic head versus capacity in US GPM at 5 feet of lift for 1/2 HP, 3/4 HP, and 1 HP models.
Figure 4: RL-SWJ100 Performance Chart
Dimensional drawing of the Red Lion RL-SWJ100 shallow well jet pump with height, length, width, and weight specifications.
Figure 5: RL-SWJ100 Dimensions

5. அமைவு மற்றும் நிறுவல்

5.1 தொகுதிtagஇ தேர்வு

The RL-SWJ100 pump is dual voltage (115/230 Volts) and comes factory-set for 230 Volts. Ensure the pump's voltage setting matches your power source. To change the voltage, remove the cover from the motor terminal box and slide the voltage indicator switch to the desired setting (115V or 230V) using a flat screwdriver.

Diagram illustrating the voltage switch on the Red Lion RL-SWJ series pump, showing positions for 230V and 115V settings.
படம் 6: தொகுதிtage Switch Settings

Video 1: This video demonstrates how to change the voltage setting on a Red Lion RL-SWJ Series Jet Pump from 230V to 115V or vice versa.

5.2 Pressure Tank Installation

If installing with a pressure tank, ensure the tank's pre-charge pressure is set correctly before installation. The pre-charge pressure should be 2 PSI below the pump's cut-in pressure setting (e.g., 28 PSI for a 30 PSI cut-in). Make all pipe connections according to local plumbing codes. Ensure the pipe size from the tank to the house is the same as the pipe size from the pump to the tank.

Video 2: This video provides instructions on how to install or adjust a pressure tank in conjunction with a jet pump system.

6. இயக்க வழிமுறைகள்

6.1 பம்பை முதன்மைப்படுத்துதல்

Before starting the pump for the first time or after it has been drained, it must be properly primed. This involves filling the pump casing and suction line with water to ensure it can create the necessary suction to draw water from the well. Refer to the detailed priming instructions in the full owner's manual for your specific setup.

6.2 ஆரம்ப தொடக்கம்

After priming and ensuring all connections are secure and leak-free, restore power to the pump. The pump should start and build pressure. Monitor the pressure gauge to ensure it reaches the desired cut-off pressure (e.g., 50 PSI for a 30/50 switch). The pump will automatically shut off once the cut-off pressure is reached.

7. பராமரிப்பு

  • வழக்கமான ஆய்வு: அவ்வப்போது அனைத்து இணைப்புகளிலும் கசிவுகள் உள்ளதா என சரிபார்த்து, பம்ப் பாதுகாப்பாக பொருத்தப்பட்டுள்ளதா என்பதை உறுதிப்படுத்தவும்.
  • அழுத்த தொட்டி சோதனை: Verify the pressure tank's air charge annually.
  • குளிர்காலமயமாக்கல்: In freezing climates, drain the pump and piping completely to prevent damage from ice expansion.
  • தூய்மை: Keep the pump area clean and free from debris to ensure proper ventilation.

8. சரிசெய்தல்

This section provides general guidance for common issues. For detailed troubleshooting steps, consult the complete owner's manual.

பொதுவான சிக்கல்கள்:

  • Pump runs but no water: Check for proper priming, ensure the suction line is submerged, and inspect for air leaks in the suction line.
  • பம்ப் சுழற்சிகள் மிகவும் அடிக்கடி: This often indicates a problem with the pressure tank (low air charge, waterlogged) or a leak in the system.
  • பம்ப் தொடங்கவில்லை: Verify electrical connections, check the circuit breaker, and ensure the voltage switch is set correctly.
  • குறைந்த அழுத்தம்: Check for clogs in the piping, inspect the impeller for damage, and verify the well's water level.

9. உத்தரவாதம் மற்றும் ஆதரவு

9.1 உத்தரவாதத் தகவல்

The Red Lion RL-SWJ100 pump comes with a 2-year manufacturer's warranty. For specific terms and conditions, please refer to the warranty details provided with your product or contact Red Lion customer support.

9.2 வாடிக்கையாளர் ஆதரவு

For troubleshooting assistance, installation guidance, or to inquire about parts and service, please contact Red Lion customer support. If your product was purchased within 30 days, refer to Amazon's return policy. For purchases beyond 30 days, consult your owner's manual or contact the seller directly if different from Amazon.com.

For additional information, visit the official Red Lion webதளம்: www.redlionproducts.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.