அறிமுகம்
This manual provides detailed instructions for the proper use and maintenance of your Apera Instruments Salt20 Salinity Tester Kit. The Salt20 is designed for professional salinity measurement in various water solutions, including pools, spas, agriculture, and environmental monitoring.
For optimal performance and longevity of your device, please read this manual thoroughly before operation.

The Apera Instruments Salt20 Salinity Tester is suitable for a wide range of applications including hydroponics, pools, and drinking water analysis.
பாதுகாப்பு முன்னெச்சரிக்கைகள்
முக்கியமான பாதுகாப்பு தகவல்
- Always handle the device with care to prevent damage to the sensor.
- Do not immerse the entire meter in water beyond the specified IP67 waterproof rating.
- Keep calibration solutions and the device out of reach of children.
- பயன்பாட்டில் இல்லாதபோது சாதனத்தை குளிர்ந்த, உலர்ந்த இடத்தில் சேமிக்கவும்.
- நீர் எதிர்ப்பைப் பராமரிக்க பேட்டரி பெட்டி சரியாக சீல் வைக்கப்பட்டுள்ளதா என்பதை உறுதிப்படுத்திக் கொள்ளுங்கள்.
தயாரிப்பு முடிந்துவிட்டதுview
கிட் கூறுகள்

The Salt20 Salinity Tester Kit includes the meter, calibration solution, AAA batteries, and a lanyard, all housed in a portable carrying case.
The Apera Instruments Salt20 Salinity Tester Kit includes:
- Salt20 Salinity Tester
- 1 bottle of calibration solution (12.88 mS/cm, equivalent to 6.44 ppt)
- AAA batteries (pre-installed or included)
- லான்யார்ட்
- எடுத்துச் செல்லக்கூடிய கேஸ்
முக்கிய அம்சங்கள்
- உயர் துல்லியம்: Apera's unique platinum black sensor (BPB) ensures high accuracy in a wide-range salinity measurement (0 to 10.0 ppt).
- Easy Auto Calibration: 1-point auto calibration with auto buffer recognition.
- தானியங்கி வெப்பநிலை இழப்பீடு (ATC): 0-50°C ATC for precise readings.
- தெளிவான LCD டிஸ்ப்ளே: Large LCD with dual display of salinity (ppt) and temperature (°C/°F), including reminders for stable readings and completed calibrations.
- நீர்ப்புகா வடிவமைப்பு: IP67 water-resistant and floatable for durability.
- நீண்ட பேட்டரி ஆயுள்: Up to 1000 hours of operation powered by AAA batteries.
- சுய நோயறிதல்: With out-of-range and low battery warnings.
சென்சார் தொழில்நுட்பம்

The Salt20 features Apera's unique Brush-Resistant Platinum Black (BPB) sensor, designed for high accuracy and consistency in wide-range salinity testing.
LCD காட்சி விவரங்கள்

The clear LCD display provides simultaneous readings for salinity (ppt) and temperature, along with indicators for stable readings and successful calibration.
துணைக்கருவிகள்

A lanyard is included for convenient and secure use of the Salt20 Salinity Tester.

The complete test kit comes in a rugged carrying case for protection and portability.
அமைவு
பேட்டரி நிறுவல்
The Salt20 Salinity Tester is powered by 4 AAA batteries.
- மீட்டரின் மேற்புறத்தில் உள்ள பேட்டரி மூடியை அவிழ்த்து விடுங்கள்.
- Insert the AAA batteries according to the polarity indicators (+/-).
- Securely screw the battery cap back on to ensure the waterproof seal.
ஆரம்ப தயாரிப்பு
- சென்சாரிலிருந்து பாதுகாப்பு தொப்பியை அகற்றவும்.
- Rinse the sensor with distilled water and gently shake off excess water.
- The meter is now ready for calibration or measurement.
இயக்க வழிமுறைகள்
அடிப்படை அளவீடு
- இயக்கு: Short press the MEAS button to turn on the meter.
- Immerse Sensor: Dip the sensor into the sample solution, ensuring the solution covers the sensor completely. Stir gently to remove air bubbles.
- அளவீட்டைப் படியுங்கள்: Wait for the smiley face icon to appear and remain stable on the LCD, indicating a stable reading. Record the salinity (ppt) and temperature (°C/°F) values.
- அணைக்க: Long press the MEAS button to turn off the meter.
மாறுதல் அலகுகள்
To switch between °C and °F, with the meter turned off, long press the CAL button until the unit changes.
அதிகாரப்பூர்வ தயாரிப்பு வீடியோ
Watch this official video from Apera Instruments for a visual guide on using the Salt20 Salinity Tester Kit. This video provides an overview of the product's features and basic operation.
அளவுத்திருத்தம்
1-Point Auto Calibration
The Salt20 Salinity Tester uses a 1-point auto calibration process with auto buffer recognition. It is recommended to calibrate the meter regularly for accurate results, especially before critical measurements or if the meter has not been used for a long time.

The Salt20 Salinity Tester features effortless single-button auto calibration with auto buffer recognition, simplifying the calibration process.
- தீர்வைத் தயாரிக்கவும்: Pour a small amount of the 12.88 mS/cm (6.44 ppt) calibration solution into a clean beaker.
- அளவுத்திருத்த பயன்முறையை உள்ளிடவும்: With the meter turned on, short press the CAL button. The display will show "CAL" and the calibration value.
- Immerse Sensor: Dip the sensor into the calibration solution. Stir gently.
- Wait for Stability: The meter will automatically recognize the calibration solution. Wait for the smiley face icon to appear and remain stable. The calibration success symbol (M) will also appear.
- அளவுத்திருத்தத்திலிருந்து வெளியேறு: Short press the MEAS button to exit calibration mode and return to measurement mode.
குறிப்பு: Always use fresh calibration solution for each calibration. Do not pour used solution back into the bottle.
பராமரிப்பு
சென்சார் சுத்தம்
The BPB (Brush-Resistant Platinum Black) sensor is robust but requires proper cleaning to maintain accuracy.
- After each use, rinse the sensor thoroughly with distilled or deionized water.
- If there is visible contamination, gently brush the sensor with a soft brush (like a soft toothbrush) while rinsing.
- For stubborn deposits, soak the sensor in a mild detergent solution for 10-15 minutes, then rinse thoroughly.
- ஒருபோதும் இல்லை wipe the sensor with abrasive materials or apply excessive force, as this can damage the platinum black coating.
சேமிப்பு
For long-term storage, ensure the sensor is clean and dry. Replace the protective cap. Store the meter in its carrying case in a cool, dry place.
சரிசெய்தல்
பொதுவான சிக்கல்கள் மற்றும் தீர்வுகள்
| பிரச்சினை | சாத்தியமான காரணம் | தீர்வு |
|---|---|---|
| துல்லியமற்ற வாசிப்புகள் | Sensor dirty; Calibration needed; Expired calibration solution | Clean sensor; Perform calibration; Use fresh calibration solution |
| No Display / Meter Won't Turn On | செயலிழந்த பேட்டரிகள்; தவறான பேட்டரி நிறுவல். | பேட்டரிகளை மாற்றவும்; பேட்டரி துருவமுனைப்பை சரிபார்க்கவும். |
| "Out-of-Range" Warning | Salinity level exceeds 10.0 ppt | The meter's range is 0-10.0 ppt. For higher ranges, a different meter is required. |
| மெதுவான பதில் | சென்சாரை சுத்தம் செய்ய வேண்டும். | Clean the sensor thoroughly |
விவரக்குறிப்புகள்
தொழில்நுட்ப விவரக்குறிப்புகள்
| அளவுரு | மதிப்பு |
|---|---|
| உப்புத்தன்மை வரம்பு | 0 - 10.0 ppt |
| Salinity Accuracy | ± 1% FS |
| வெப்பநிலை வரம்பு | 0 - 50°C (32 - 122°F) |
| வெப்பநிலை இழப்பீடு | Automatic (0-50°C) |
| அளவுத்திருத்தம் | Auto 1-point |
| பவர் சப்ளை | 4 x AAA பேட்டரிகள் |
| பேட்டரி ஆயுள் | 1000 மணி நேரம் வரை |
| நீர்ப்புகா மதிப்பீடு | IP67 (Dust-proof and Water-proof, Floatable) |
| ஆட்டோ பவர் ஆஃப் | 8 minutes of no operation |
| பரிமாணங்கள் | 7.01 x 1.61 x 1.18 அங்குலம் |
| எடை | 3.8 அவுன்ஸ் |
உத்தரவாதம் மற்றும் ஆதரவு
உத்தரவாத தகவல்
Apera Instruments provides a limited warranty for its products. Please refer to the official Apera Instruments website or the warranty card included with your product for specific warranty terms and conditions.
வாடிக்கையாளர் ஆதரவு
For technical assistance, troubleshooting, or inquiries about replacement parts and accessories, please contact Apera Instruments customer support.
Webதளம்: www.aperainst.com
மின்னஞ்சல்: குறிப்பிட்ட தொடர்பு மின்னஞ்சலுக்கு உங்கள் தயாரிப்பு ஆவணங்களைப் பார்க்கவும்.