The Apera Instruments EC820 Benchtop Conductivity Meter is a high-precision instrument designed for accurate measurement of Conductivity (EC), Total Dissolved Solids (TDS), Salinity, Resistivity, and temperature. This meter is equipped with advanced features for reliable and stable readings across a wide range of applications.
This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your EC820 meter to ensure optimal performance and longevity.

Figure 1: Apera Instruments EC820 Benchtop Conductivity Meter Kit. The image shows the main meter unit, a flexible electrode arm and holder, and the conductivity electrode submerged in a beaker of liquid.
2. பாதுகாப்பு முன்னெச்சரிக்கைகள்
- Always handle the meter and electrodes with care to prevent damage.
- Do not immerse the main meter unit in water. The unit is IP54 water-resistant, but not submersible.
- வழங்கப்பட்ட பவர் அடாப்டரை மட்டும் பயன்படுத்தவும்.
- Keep calibration solutions and samples away from children and pets. Follow safety data sheets (SDS) for handling specific chemicals.
- Ensure the meter is placed on a stable, level surface during operation.
- சுத்தம் செய்வதற்கு அல்லது பராமரிப்பதற்கு முன் மின்சாரத்தைத் துண்டிக்கவும்.
3. தொகுப்பு உள்ளடக்கங்கள்
கீழே பட்டியலிடப்பட்டுள்ள அனைத்து பொருட்களும் உங்கள் தொகுப்பில் உள்ளதா என்பதைச் சரிபார்க்கவும்:
- EC820 துல்லியமான பெஞ்ச்டாப் கடத்துத்திறன் மீட்டர்
- 2401T-F Platinum Glass-body Conductivity Electrode
- Flexible Electrode Arm and Holder
- USB கேபிள்
- PC-Link Software Flash Drive
- Power Adaptor (Input: 120V AC 60Hz; Output: 9V 300mA)
- Calibration Solutions:
- 84 µS/cm (1 vial)
- 1413 µS/cm (1 vial)
- 12.88 mS/cm (1 vial)

Figure 2: The 2401T-F Platinum Glass-body Conductivity Electrode, showing its connection cables.
4 அமைவு
- Unpack the Meter: பேக்கேஜிங்கிலிருந்து அனைத்து கூறுகளையும் கவனமாக அகற்றவும்.
- Assemble Electrode Arm: Attach the flexible electrode arm to the meter unit. Ensure it is securely fastened.
- Connect Electrode: Plug the 2401T-F Conductivity Electrode into the designated "COND" port on the back of the meter. Ensure the connection is firm.

Figure 3: Rear panel of the EC820 meter, highlighting the "COND" and "TEMP" ports, along with RS232 and DC 9V power input.
- பவர் இணைக்கவும்: Plug the power adapter into the "DC 9V" port on the back of the meter, then connect it to a standard 120V AC 60Hz power outlet.
- ஆரம்ப பவர் ஆன்: Press the power button to turn on the meter. The LCD display should illuminate.
5. இயக்க வழிமுறைகள்
5.1. அளவுத்திருத்தம்
The EC820 meter features 1 to 4 points auto-calibration. Regular calibration ensures accurate measurements.
- Prepare Solutions: Use the provided 84 µS/cm, 1413 µS/cm, and 12.88 mS/cm calibration solutions. Ensure solutions are at room temperature.
- மின்முனையை அலசுங்கள்: Rinse the conductivity electrode thoroughly with distilled or deionized water before and after each measurement or calibration. Gently blot dry with a lint-free tissue.
- அளவுத்திருத்த பயன்முறையை உள்ளிடவும்: With the meter on, press the CAL button. The display will show "CAL" and prompt for the first calibration point.
- முதல் புள்ளி அளவுத்திருத்தம்: Immerse the electrode into the 1413 µS/cm standard solution. Wait for the reading to stabilize (indicated by a stable icon on the display). The meter will automatically recognize the solution. Press உள்ளிடவும் உறுதி செய்ய.
- Subsequent Points (Optional): For higher accuracy, proceed with 84 µS/cm and 12.88 mS/cm solutions following the same procedure. The meter will guide you through the process.
- அளவுத்திருத்தத்திலிருந்து வெளியேறு: After completing desired calibration points, press the MEAS button to return to measurement mode.
குறிப்பு: The meter has a self-diagnosis function to help identify and fix common calibration problems. Refer to the on-screen prompts.
5.2. அளவீடு
- மின்முனையை அலசுங்கள்: காய்ச்சி வடிகட்டிய நீரில் மின்முனையை துவைக்கவும்.
- மின்முனையை மூழ்கடி: மின்முனையை s-க்குள் மூழ்கடிக்கவும்.ample solution, ensuring the sensor is fully submerged.
- Wait for Stability: Allow the reading to stabilize. The stable reading icon will appear on the LCD.
- பதிவு வாசிப்பு: Read the Conductivity (EC), TDS, Salinity, or Resistivity value displayed on the large LCD. Temperature will also be displayed simultaneously.
- அலகுகளை மாற்றவும்: அழுத்தவும் UNIT button to cycle through different measurement units (e.g., µS/cm, mS/cm, ppm, ppt).
- தரவு சேமிப்பு: The meter supports GLP data management with 500 groups of data storage. Use the M+ / R-M buttons to store and recall data.
- தரவு ஏற்றுமதி: Connect the meter to a PC via the USB cable and use the provided PC-Link software (Windows-based system only) to export data.
6. பராமரிப்பு
- மின்முனையை சுத்தம் செய்தல்:
- Regularly rinse the electrode with distilled or deionized water.
- For stubborn deposits, refer to the electrode's specific cleaning instructions. Generally, a mild detergent solution or a specific electrode cleaning solution can be used, followed by thorough rinsing.
- Do not scratch or damage the platinum black sensor.
- மின்முனை சேமிப்பு:
- Always store the conductivity electrode in its protective cap filled with a proper electrode storage solution (e.g., 3M KCl solution or Apera Instruments storage solution). Never store dry.
- மீட்டர் சுத்தம் செய்தல்: Wipe the main meter unit with a clean, damp துணி. சிராய்ப்பு கிளீனர்கள் அல்லது கரைப்பான்களைப் பயன்படுத்த வேண்டாம்.
- மென்பொருள் புதுப்பிப்புகள்: Check the Apera Instruments website periodically for any software updates for the PC-Link software.

படம் 4: நெருக்கமான காட்சி view of the platinum glass-body conductivity electrode tip, which requires careful handling and proper storage.
7. சரிசெய்தல்
| பிரச்சனை | சாத்தியமான காரணம் | தீர்வு |
|---|---|---|
| மீட்டர் இயக்கப்படவில்லை. | மின்சாரம் இல்லை; தவறான அடாப்டர்; தளர்வான இணைப்பு. | Check power adapter connection and outlet. Ensure adapter is functional. |
| நிலையற்ற அளவீடுகள் | Dirty electrode; air bubbles on sensor; incorrect calibration; temperature fluctuations. | Clean electrode; gently tap electrode to remove bubbles; recalibrate meter; ensure sample temperature is stable. |
| அளவுத்திருத்தப் பிழை | Contaminated calibration solution; incorrect solution used; damaged electrode. | Use fresh calibration solutions; ensure correct solution for calibration point; inspect electrode for damage. |
| No data transfer to PC | Incorrect USB connection; software not installed or running; driver issues. | Verify USB cable connection; ensure PC-Link software is installed and open; check device manager for driver issues. |
8. விவரக்குறிப்புகள்
| அளவுரு | மதிப்பு |
|---|---|
| மாதிரி எண் | AI532 |
| அளவீட்டு அளவுருக்கள் | Conductivity (EC), TDS, Salinity, Resistivity, Temperature |
| கடத்துத்திறன் வரம்பு | 0 to 2,000 mS |
| துல்லியம் | ± 0.5% FS |
| அளவுத்திருத்த புள்ளிகள் | 1 to 4 points auto-calibration (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm) |
| வெப்பநிலை இழப்பீடு | தானியங்கி வெப்பநிலை இழப்பீடு (ATC) |
| தரவு சேமிப்பு | 500 groups (GLP compliant) |
| இணைப்பு | USB for PC data export |
| காட்சி வகை | பெரிய பின்னொளி எல்சிடி |
| பவர் சப்ளை | 9V DC, 300mA (120V AC 60Hz adapter included) |
| நுழைவு பாதுகாப்பு | IP54 நீர்-எதிர்ப்பு |
| சான்றிதழ்கள் | CE, RoHS, ISO 9001:2015 |
| தொகுப்பு பரிமாணங்கள் | 10.63 x 9.88 x 6.61 அங்குலம் |
| எடை | 6.5 பவுண்டுகள் |
9. உத்தரவாதம் மற்றும் ஆதரவு
Apera Instruments products are manufactured under an ISO 9001:2015 certified quality system, ensuring high standards of quality and reliability. For specific warranty information and technical support, please refer to the warranty card included with your product or visit the official Apera Instruments webதளம்.
For assistance with troubleshooting, calibration, or general inquiries, please contact Apera Instruments customer service. Contact details can typically be found on their official webதளம் அல்லது தயாரிப்பு பேக்கேஜிங்கில்.
ஆன்லைன் ஆதாரங்கள்: Apera Instruments Store on Amazon
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.