CDN AD-DTP392

அறிவுறுத்தல் கையேடு

CDN AD-DTP392 Replacement Probe

Model: AD-DTP392 | Brand: CDN

1. தயாரிப்பு முடிந்துவிட்டதுview

The CDN AD-DTP392 is a replacement probe specifically designed for use with CDN DTP392 Probe Thermometers. This probe is essential for accurate temperature measurement in various applications, particularly in cooking and food preparation.

CDN AD-DTP392 Replacement Probe

Image 1: The CDN AD-DTP392 replacement probe, featuring a stainless steel tip and braided cable with a 3.5mm jack connector.

Constructed from durable stainless steel, the probe is designed for longevity and reliable performance. Its compact dimensions ensure ease of use and storage.

  • இணக்கத்தன்மை: Specifically designed for CDN DTP392 Probe Thermometers.
  • பொருள்: Stainless Steel for the probe tip, ensuring durability and food safety.
  • பரிமாணங்கள்: Approximately 9 x 5.5 x 0.1 inches; weighs about 0.8 ounces.

2. அமைவு மற்றும் நிறுவல்

To set up your CDN AD-DTP392 replacement probe, follow these simple steps:

  1. இணக்கத்தன்மையை உறுதிப்படுத்தவும்: Verify that your thermometer unit is a CDN DTP392 model. This probe is designed exclusively for this specific model.
  2. Locate Probe Port: Identify the probe input port on your CDN DTP392 thermometer. This is typically a 3.5mm (1/8") audio jack style port.
  3. ஆய்வைச் செருகவும்: Carefully insert the probe's jack connector into the thermometer's probe port. Ensure it is fully seated to establish a secure connection.
  4. பாதுகாப்பான இடம்: If your thermometer unit has a magnet or stand, ensure it is placed securely on a stable surface or attached to a magnetic surface for easy viewபயன்பாட்டின் போது.
CDN DTP392 Probe Thermometer with Specifications

Image 2: The CDN DTP392 Probe Thermometer, for which the AD-DTP392 is a replacement probe. This image also displays key specifications of the thermometer unit.

3. இயக்க வழிமுறைகள்

Once the AD-DTP392 probe is connected to your CDN DTP392 thermometer, you can begin taking temperature readings:

  1. பவர் ஆன்: Turn on your CDN DTP392 thermometer unit. The display should activate and show the current temperature reading from the connected probe.
  2. Insert Probe into Food: Carefully insert the stainless steel probe tip into the thickest part of the food item you wish to measure, avoiding bones.
  3. கண்காணிப்பு வெப்பநிலை: Observe the temperature reading on the thermometer's display. The DTP392 thermometer provides temperature accuracy within a range of 32-104°F (±4°F), 105-212°F (±6°F), and 213-320°F (±10°F).
  4. வெப்ப எதிர்ப்பு: The heat sensor cable is designed to withstand temperatures up to 400°F (204°C). Ensure the cable is not exposed to temperatures exceeding this limit to prevent damage.
  5. அலாரம் செயல்பாடு: Utilize the thermometer's alarm feature (if applicable) to set desired target temperatures. The alarm will sound when the target temperature is reached.

4. பராமரிப்பு மற்றும் பராமரிப்பு

Proper maintenance ensures the longevity and accuracy of your AD-DTP392 replacement probe:

  • சுத்தம்: After each use, wipe the stainless steel probe tip clean with a damp cloth. For thorough cleaning, use mild soap and water. Ensure the probe tip is completely dry before storage.
  • மூழ்குவதைத் தவிர்க்கவும்: Do not immerse the entire probe or its connector in water or any other liquid, as this can damage the internal electronics. Only the stainless steel tip is designed for contact with food.
  • சேமிப்பு: Store the probe in a clean, dry place when not in use. Avoid kinking or sharply bending the cable, especially near the probe tip or connector, as this can damage the internal wiring.
  • வெப்பநிலை வரம்புகள்: Adhere to the specified temperature limits for the probe and cable (up to 400°F / 204°C for the cable). Exceeding these temperatures can cause permanent damage.

5. சரிசெய்தல்

If you encounter issues with your AD-DTP392 replacement probe, consider the following:

  • வாசிப்பு இல்லை அல்லது துல்லியமற்ற வாசிப்பு:
    • இணைப்பைச் சரிபார்க்கவும்: Ensure the probe's jack is fully and securely inserted into the thermometer's port. A loose connection can lead to intermittent or no readings.
    • இணக்கத்தன்மை: Confirm that your thermometer is indeed a CDN DTP392 model. This probe is not universally compatible with all thermometer brands or models, even if the jack size is similar. Incompatibility can lead to incorrect temperature displays.
    • Probe Damage: Inspect the probe cable for any visible signs of damage, such as kinks, cuts, or exposed wires. Internal wire damage, often near the probe tip or connector due to repeated bending, can cause inaccurate readings or complete failure.
    • Temperature Exceeded: If the probe or cable was exposed to temperatures above its maximum limit (400°F / 204°C), it might be permanently damaged.
  • இடைப்பட்ட வாசிப்புகள்:
    • This often indicates a loose connection or a damaged internal wire that makes contact intermittently. Try wiggling the connector gently to see if the reading stabilizes.

If troubleshooting steps do not resolve the issue, the probe may need to be replaced. Consider contacting CDN customer support for further assistance.

6. விவரக்குறிப்புகள்

அம்சம்விவரம்
மாதிரி எண்AD-DTP392
பிராண்ட்CDN
தயாரிப்பு பரிமாணங்கள்9 x 5.5 x 0.1 அங்குலம்
பொருளின் எடை0.8 அவுன்ஸ்
வெளிப்புற பொருள்துருப்பிடிக்காத எஃகு
தயாரிப்பு பராமரிப்பு வழிமுறைகள்துடைக்க சுத்தம்
முதல் தேதி கிடைக்கும்ஜூலை 19, 2004

7. உத்தரவாதத் தகவல்

The CDN DTP392 Probe Thermometer, for which this probe is a replacement, typically comes with a 5 வருட வரையறுக்கப்பட்ட உத்தரவாதம் from the manufacturer. Please refer to the original thermometer's documentation or the manufacturer's website for specific warranty terms and conditions applicable to replacement parts.

Note: Warranty terms may vary and are subject to the manufacturer's policies at the time of purchase.

8. வாடிக்கையாளர் ஆதரவு

For further assistance, technical support, or inquiries regarding your CDN AD-DTP392 Replacement Probe or CDN DTP392 Thermometer, please contact the manufacturer:

  • உற்பத்தியாளர்: Component Design Northwest, Inc. (CDN)
  • முகவரி: PO Box 10947, Portland, OR 97296-0947
  • தொலைபேசி: 800-338-5594
  • தொலைநகல்: 800-879-2364
  • மின்னஞ்சல்: info@cdn-timeandtemp.com
  • Webதளம்: www.cdn-timeandtemp.com

Please have your product model number (AD-DTP392) and purchase information ready when contacting support.

தொடர்புடைய ஆவணங்கள் - AD-DTP392

முன்view CDN BT482 Bluetooth Dual Probe Thermometer & Timer User Manual
Comprehensive user manual for the CDN BT482 Bluetooth Dual Probe Thermometer & Timer, covering features, setup, operation, temperature guides, specifications, and precautions. Monitor cooking remotely via iOS and Android devices.
முன்view CDN BT482 Bluetooth Dual Probe Thermometer & Timer User Manual
Comprehensive user manual for the CDN BT482 Bluetooth Dual Probe Thermometer & Timer, covering setup, operation, app features, temperature guides, and precautions.
முன்view CDN DTTC Combo Probe Thermometer, Timer & Clock - User Manual and Specifications
Comprehensive guide for the CDN DTTC Combo Probe Thermometer, Timer & Clock. Learn about its features, operating instructions, temperature guides for cooking, candy making, and deep frying, plus specifications, precautions, and warranty information.
முன்view CDN DSP1 Dual-Sensing Probe Thermometer/Timer: User Manual & Guide
Comprehensive guide for the CDN DSP1 Dual-Sensing Probe Thermometer/Timer. Learn about features, operating instructions, food safety temperatures, candy making guides, and specifications.
முன்view CDN DT392 டிஜிட்டல் தெர்மோமீட்டர் - பயனர் வழிகாட்டி மற்றும் விவரக்குறிப்புகள்
CDN DT392 டிஜிட்டல் தெர்மோமீட்டருக்கான விரிவான வழிகாட்டி, அம்சங்கள், செயல்பாடு, பேட்டரி மாற்றீடு, உணவு பாதுகாப்பு வெப்பநிலை மற்றும் உத்தரவாதத் தகவல் ஆகியவற்றை விவரிக்கிறது. பொது நோக்கத்திற்கான சமையலுக்கு ஏற்றது.
முன்view CDN DTC450 Digital Candy Thermometer User Manual and Specifications
Comprehensive guide for the CDN DTC450 Digital Candy Thermometer, covering features, operation, temperature charts, care, and specifications. Ideal for candy making and high-temperature cooking.