Renishaw OMP60

ரெனிஷா OMP60 மெஷின் டூல் ப்ரோப் கிட் பயனர் கையேடு

Model: OMP60

1. அறிமுகம்

This manual provides essential information for the safe and effective use of the Renishaw OMP60 Machine Tool Probe Kit. The OMP60 is a compact 3D touch-trigger probe designed for workpiece set-up and inspection on a wide range of medium and large machining centers. It utilizes optical signal transmission for reliable communication. Proper understanding and adherence to these instructions will ensure optimal performance and longevity of your Renishaw OMP60 probe.

2. தயாரிப்பு முடிந்துவிட்டதுview

The Renishaw OMP60 probe is engineered to enhance manufacturing efficiency by reducing set-up times, minimizing scrap, and lowering fixture costs. Its robust design and optical signal transmission system ensure high accuracy and reliability in demanding industrial environments. The probe is compatible with both legacy and new generation Renishaw optical receivers, facilitating seamless integration into existing machine setups.

முக்கிய அம்சங்கள் அடங்கும்:

  • Compact 3D touch-trigger design.
  • Optical signal transmission for reliable data transfer.
  • Suitable for workpiece set-up and inspection.
  • Broad compatibility with Renishaw optical receivers.

3. பாதுகாப்பு தகவல்

Always observe standard safety precautions when working with machine tools and precision equipment. Failure to do so may result in injury or damage to the equipment.

  • Ensure the machine tool is powered off and locked out before installing or removing the probe.
  • Handle the probe with care to prevent damage to its precision components.
  • Only use approved accessories and replacement parts from Renishaw.
  • Refer to your machine tool's operating manual for specific safety guidelines related to probe usage.
  • உள்ளூர் விதிமுறைகளின்படி பேட்டரிகளை அகற்றவும்.

4. தொகுப்பு உள்ளடக்கங்கள்

Upon opening your Renishaw OMP60 Machine Tool Probe Kit, verify that all components are present and undamaged. The standard kit typically includes the following items:

Renishaw OMP60 probe kit in its original packaging

Image: The Renishaw OMP60 probe kit as received in its original cardboard packaging, showing the probe unit, a quick-start guide, two AA batteries, and a small toolkit.

Contents of the Renishaw OMP60 probe kit laid out

Image: The individual components of the Renishaw OMP60 probe kit laid out, including the OMP60 probe, a quick-start guide, two Duracell AA alkaline batteries, and a small plastic bag containing a toolkit (likely styli or adjustment tools).

  • Renishaw OMP60 Probe Unit
  • Quick-start Guide (A-1038-8501)
  • AA Alkaline Batteries (typically 2)
  • OMP60 Toolkit (RMP/OMP60 TOOLKIT A-4038-0208-02)

5 அமைவு

Follow these general steps for setting up your Renishaw OMP60 probe. For detailed, model-specific instructions, refer to the included Quick-start Guide and the comprehensive Renishaw OMP60 installation manual.

  1. பேக்கிங் மற்றும் ஆய்வு: Carefully remove all components from the packaging. Inspect the probe and accessories for any signs of damage.
  2. பேட்டரி நிறுவல்: Access the battery compartment, typically located at the bottom of the probe. Insert the provided AA batteries, ensuring correct polarity. Securely close the compartment.
  3. ஸ்டைலஸ் இணைப்பு: Select the appropriate stylus for your application. Carefully thread the stylus onto the probe's mounting point. Ensure it is securely fastened but do not overtighten.
  4. ஆய்வை ஏற்றுதல்: Mount the OMP60 probe into the machine tool spindle or tool holder. Ensure it is seated correctly and securely clampஎட்.
  5. Optical Receiver Setup: Ensure your Renishaw optical receiver (e.g., OMI-2, OMI-2T) is correctly installed and aligned with the probe's optical transmission window. Refer to the receiver's manual for installation and alignment procedures.
  6. Machine Control Integration: Configure your machine tool's CNC control system to recognize and communicate with the OMP60 probe. This typically involves setting up probe cycles and offset registers.
  7. ஆரம்ப அளவுத்திருத்தம்: Perform an initial calibration of the probe using a known reference artifact (e.g., a calibration sphere). This establishes the probe's trigger points and ensures measurement accuracy.
Close-up of the Renishaw OMP60 probe

படம்: ஒரு விரிவான view of the Renishaw OMP60 probe unit, highlighting the branding, model number, and 'MADE IN UK' inscription. This view shows the main body and the transparent section revealing internal electronics.

மேல் view of the Renishaw OMP60 probe

படம்: மேலிருந்து கீழ் நோக்கி view of the Renishaw OMP60 probe, showing the central stylus mounting point with a hexagonal socket and surrounding adjustment mechanisms.

6. இயக்க வழிமுறைகள்

The Renishaw OMP60 probe is designed for automated workpiece measurement and inspection cycles within a machine tool environment. Operation is typically controlled via the machine's CNC system.

  1. நிரல் தேர்வு: Select the appropriate probing cycle program on your machine tool's CNC control. These programs are designed for specific measurement tasks, such as workpiece alignment, feature measurement, or tool setting.
  2. பணிப்பகுதி தயாரிப்பு: பணிப்பகுதி பாதுகாப்பாக cl இருப்பதை உறுதி செய்யவும்amped and positioned on the machine table.
  3. Cycle Execution: Initiate the probing cycle from the CNC control. The machine will automatically move the probe to the designated measurement points.
  4. தரவு விளக்கம்: The measurement data collected by the OMP60 probe is transmitted to the CNC control, where it can be used to update work offsets, perform in-process inspection, or generate reports.

For detailed programming examples and specific operational sequences, consult the Renishaw OMP60 user manual and your machine tool's programming guide.

Renishaw OMP60 probe showing trigger force adjustment

படம்: ஒரு நெருக்கமான படம் view of the Renishaw OMP60 probe, indicating the 'TRIGGER FORCE' adjustment screw with directional arrows for increasinகிராம் அல்லது குறைவுasing the trigger force. This adjustment allows fine-tuning of the probe's sensitivity.

7. பராமரிப்பு

Regular maintenance ensures the continued accuracy and reliability of your Renishaw OMP60 probe.

  • சுத்தம்: Periodically clean the probe's exterior, especially the optical transmission window, using a soft, lint-free cloth. Avoid abrasive cleaners or solvents.
  • ஸ்டைலஸ் ஆய்வு: Regularly inspect the stylus for wear, damage, or contamination. Replace damaged styli immediately to maintain measurement accuracy.
  • பேட்டரி மாற்று: Replace batteries when the low battery indicator is displayed or when performance degrades. Always use high-quality alkaline batteries.
  • சேமிப்பு: When not in use, store the probe in a clean, dry environment, preferably in its original packaging or a protective case.
கீழே view of the Renishaw OMP60 probe

Image: A bottom view of the Renishaw OMP60 probe, showing the battery compartment cover with three securing screws and a central access point.

8. சரிசெய்தல்

This section addresses common issues you might encounter with the OMP60 probe. For more complex problems, contact Renishaw technical support.

பிரச்சனைசாத்தியமான காரணம்தீர்வு
Probe not activatingகுறைந்த அல்லது இறந்த பேட்டரிகள்
Incorrect optical receiver alignment
Obstruction of optical path
Machine control error
பேட்டரிகளை மாற்றவும்
Re-align optical receiver
Clean optical window and ensure clear path
Check CNC program and machine status
தவறான அளவீடுகள்Damaged or worn stylus
Probe not calibrated
Contamination on stylus or workpiece
Incorrect trigger force setting
Replace stylus
Perform probe calibration
Clean stylus and workpiece
Adjust trigger force (refer to Section 6 image)
Intermittent signal lossபலவீனமான பேட்டரிகள்
சுற்றுச்சூழல் குறுக்கீடு
Partial obstruction of optical path
பேட்டரிகளை மாற்றவும்
Minimize sources of optical interference
Ensure clear line of sight between probe and receiver

9. விவரக்குறிப்புகள்

The Renishaw OMP60 is a precision instrument. Key specifications include:

  • ஆய்வு வகை: 3D Touch-Trigger Probe
  • பரவும் முறை: ஆப்டிகல்
  • சக்தி ஆதாரம்: ஏஏ பேட்டரிகள்
  • தொகுப்பு அளவுகள்: தோராயமாக 10 x 8 x 5 அங்குலங்கள் (254 x 203 x 127 மிமீ)
  • உற்பத்தியாளர்: ரெனிஷா
  • பிறப்பிடமான நாடு: United Kingdom (as indicated on the probe)

For detailed technical specifications, including trigger force ranges, measurement repeatability, and environmental operating conditions, please refer to the official Renishaw OMP60 product data sheet or the full user manual available from Renishaw.

10. உத்தரவாதம் மற்றும் ஆதரவு

The Renishaw OMP60 Machine Tool Probe Kit typically comes with a manufacturer's warranty. Specific warranty terms and conditions are usually provided with the product documentation or can be obtained directly from Renishaw or your authorized distributor. It is recommended to register your product upon purchase to facilitate any warranty claims.

For technical assistance, service, or to inquire about replacement parts, please contact Renishaw customer support or your local Renishaw representative. Contact information can be found on the official Renishaw webதளம் (www.renishaw.com).

தொடர்புடைய ஆவணங்கள் - OMP60

முன்view இயந்திர கருவிகளுக்கான ரெனிஷா ஆய்வு மென்பொருள்: நிரல்கள் மற்றும் அம்சங்கள்
இயந்திர கருவிகள், விரிவான நிரல்கள் மற்றும் இயந்திர மையங்கள், லேத்கள் மற்றும் பல-அச்சு பயன்பாடுகளுக்கான அம்சங்களை ரெனிஷாவின் விரிவான ஆய்வு மென்பொருளை ஆராயுங்கள். மேம்பட்ட உற்பத்தி செயல்திறனுக்காக இன்ஸ்பெக்ஷன் பிளஸ், உற்பத்தித்திறன்+™ ஸ்கேனிங் சூட், ஆக்சிசெட்™ செக்-அப் மற்றும் ஸ்மார்ட்போன் பயன்பாடுகளைக் கண்டறியவும்.
முன்view OMM-2C நிறுவல் வழிகாட்டியுடன் கூடிய ரெனிஷா OSI/OSI-D: கணினி அமைப்பு மற்றும் செயல்பாடு
OMM-2C பல ஆப்டிகல் ஆய்வு இடைமுக அமைப்புடன் கூடிய ரெனிஷா OSI/OSI-D க்கான விரிவான நிறுவல் வழிகாட்டி. தொழில்துறை CNC பயன்பாடுகளுக்கான அமைப்பு, உள்ளமைவு, பராமரிப்பு மற்றும் சரிசெய்தல் ஆகியவற்றை உள்ளடக்கியது.
முன்view ரெனிஷா RMP60 விரைவு-தொடக்க வழிகாட்டி
ரெனிஷா RMP60 ரேடியோ ஆய்வுக்கான விரைவு-தொடக்க வழிகாட்டி, இயந்திர கருவி ஆய்வுக்கான ஆரம்ப அமைப்பு மற்றும் செயல்பாட்டை விவரிக்கிறது.
முன்view ரெனிஷா OMP40-2 ஆப்டிகல் மெஷின் ஆய்வு நிறுவல் வழிகாட்டி
இந்த வழிகாட்டி, CNC இயந்திர சூழல்களில் தானியங்கி பணிக்கருவி ஆய்வு மற்றும் பணி அமைப்பிற்கான முக்கிய அங்கமான Renishaw OMP40-2 ஆப்டிகல் இயந்திர ஆய்வுக்கான விரிவான நிறுவல், அமைப்பு மற்றும் உள்ளமைவு விவரங்களை வழங்குகிறது.
முன்view ரெனிஷா: ஸ்ப்பெக்டர் ரெஷெனி டுல்யா காண்ட்ரோல் ப்ரோஷெஸ்ஸோவ் ஒப்ராபோட்கி நா ஸ்டான்காக் ஸ் க்ச்ப்யூ
ரெனிஷா பொவிஷாயுட் கசெஸ்ட்வோ, டோச்னோஸ்ட் மற்றும் ப்ரோயிஸ்வோடிடெல்னோஸ்ட் ஸ்டான்கோவ்ஸ். Полный обзор решений для kontrolya prochessov оbrabotki.
முன்view Renishaw RMP60 (QE) Radio Machine Probe Installation Guide
Comprehensive installation guide for the Renishaw RMP60 (QE) radio machine probe. Covers setup, configuration, system integration with RMI-Q/RMI-QE, maintenance, and troubleshooting for industrial metrology applications.