SEBSON 2_X_HF_CEIL_A

SEBSON HF Motion Detector Instruction Manual

Model: 2_X_HF_CEIL_A | Brand: SEBSON

1. அறிமுகம்

This manual provides detailed instructions for the installation, operation, and maintenance of your SEBSON HF Motion Detector (Model 2_X_HF_CEIL_A). Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.

SEBSON HF Motion Detector, front view

படம் 1.1: முன் view of the SEBSON HF Motion Detector. This image shows the circular, white casing of the motion detector, designed for discreet ceiling surface mounting.

2. பாதுகாப்பு வழிமுறைகள்

  • Installation must be performed by a qualified electrician in accordance with national wiring regulations.
  • Disconnect power before installation or any maintenance.
  • Do not exceed the maximum load capacity: 800W for incandescent lamps, 300W for LED or other energy-saving lamps.
  • This device is designed for indoor use only (IP20 rating). Do not expose to moisture or extreme temperatures.
  • Ensure the mounting surface is stable and can support the device.
  • குழந்தைகளுக்கு எட்டாத இடத்தில் வைக்கவும்.

3. தயாரிப்பு முடிந்துவிட்டதுview

The SEBSON HF Motion Detector utilizes high-frequency (HF) technology to detect movement within its coverage area. It is designed for ceiling surface mounting and offers adjustable settings for optimal performance in various indoor environments.

முக்கிய அம்சங்கள்:

  • High-Frequency Sensor: Detects movement through non-metallic objects like thin walls or doors.
  • பரந்த கவரேஜ்: 360° detection angle with a range of 2 to 16 meters.
  • சரிசெய்யக்கூடிய அமைப்புகள்: Time delay (10 seconds to 12 minutes), sensitivity (detection range), and ambient light threshold (3-2000 lux).
  • LED இணக்கமானது: Supports up to 300W for LED lamps and 800W for incandescent lamps.
  • சிறிய வடிவமைப்பு: Circular, white casing with dimensions of Ø100x22mm.
SEBSON HF Motion Detector with key specifications

படம் 3.1: முடிந்ததுview of the motion detector highlighting its key specifications including detection range, LED compatibility, IP rating, time delay, lux range, and voltage.

4. விவரக்குறிப்புகள்

பிராண்ட்செப்சன்
மாதிரி எண்2_X_HF_CEIL_A
பரிமாணங்கள் (Ø x H)100 மிமீ x 22 மிமீ
எடை280 கிராம்
நிறம்வெள்ளை
பொருள்பிளாஸ்டிக்
சக்தி ஆதாரம்AC
தொகுதிtage230 வோல்ட்
அதிகபட்ச சுமை (ஒளிரும்)800 வாட்ஸ்
Max Load (LED/Energy-saving)300 வாட்ஸ்
கண்டறிதல் தொழில்நுட்பம்High-Frequency (HF)
கண்டறிதல் கோணம்360°
கண்டறிதல் வரம்பு2 - 16 meters (adjustable)
கால தாமதம்10 seconds - 12 minutes (adjustable)
Ambient Light Setting (LUX)3 - 2000 lux (adjustable)
நிறுவல் வகைஉச்சவரம்பு மேற்பரப்பு மவுண்ட்
ஐபி மதிப்பீடுIP20 (உட்புற உபயோகம் மட்டும்)
Dimensional drawing of the SEBSON HF Motion Detector

Image 4.1: Technical drawing showing the dimensions of the motion detector: 100mm diameter and 22mm height.

5. நிறுவல் (அமைவு)

முக்கியமானது: Ensure the main power supply is switched off before commencing installation.

  1. இருப்பிடத்தைத் தேர்வுசெய்க: Select a suitable indoor ceiling location for surface mounting. Avoid placing near heat sources, air conditioning vents, or areas with significant air movement, which can interfere with detection.
  2. வயரிங் தயார் செய்யவும்: c ஐ திறக்கவும்asing of the motion detector. You will find terminals for Live (L), Neutral (N), and Switched Live (L').
  3. மவுண்ட் பேஸ்: Secure the base of the motion detector to the ceiling using appropriate screws and wall plugs. Ensure the cable entry points are aligned.
  4. கம்பி இணைப்புகள்:
    • Connect the incoming Live wire to the 'L' terminal.
    • Connect the incoming Neutral wire to the 'N' terminal.
    • Connect the Live wire to your light fixture (load) to the 'L'' terminal.
    • Connect the Neutral wire from your light fixture (load) to the 'N' terminal (shared with incoming neutral).
    மீண்டும் view of the SEBSON HF Motion Detector showing wiring terminals and adjustment dials

    படம் 5.1: பின்புறம் view of the motion detector, illustrating the wiring terminals (L, N, L') and the three adjustable dials for TIME, SENS, and LUX settings.

  5. மூடு Casing: Once wiring is complete and secure, reattach the main body of the detector to its base.
  6. சக்தியை மீட்டமை: Switch on the main power supply. The detector will enter a warm-up period (typically 30-60 seconds) during which it may switch on and off randomly.

6. Operation and Settings Adjustment

The SEBSON HF Motion Detector features three adjustable dials to customize its operation:

  • TIME (Time Delay): Controls how long the connected light remains on after the last detected movement.
    • 10 வினாடிகள் முதல் 12 நிமிடங்கள் வரை சரிசெய்யக்கூடியது.
    • Turn clockwise to increase the time delay, counter-clockwise to decrease.
  • SENS (Sensitivity/Detection Range): Adjusts the detection range of the HF sensor.
    • Adjustable from 2 meters to 16 meters.
    • Turn clockwise for higher sensitivity (longer range), counter-clockwise for lower sensitivity (shorter range).
    • Consider the environment to avoid unwanted detections (e.g., through thin walls).
  • LUX (Ambient Light Threshold): Determines the ambient light level at which the sensor will activate the connected light.
    • 3 லக்ஸ் (இருள்) முதல் 2000 லக்ஸ் (பகல்) வரை சரிசெய்யக்கூடியது.
    • Turn towards the sun icon for activation in brighter conditions (daylight).
    • Turn towards the moon icon for activation only in darker conditions (night).
Close-up of the adjustment dials on the SEBSON HF Motion Detector

படம் 6.1: ஒரு விரிவான view of the three rotary dials on the motion detector, labeled TIME, SENS, and LUX, used for fine-tuning operational parameters.

Diagram illustrating detection range and adjustment dial functions

Image 6.2: A diagram showing the 360° detection pattern and adjustable range (2-16m) from a ceiling mount, along with visual representations of the LUX, SENS, and TIME adjustment dials.

7. பராமரிப்பு

The SEBSON HF Motion Detector requires minimal maintenance. Follow these guidelines:

  • சுத்தம்: Gently wipe the surface of the detector with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the device.
  • ஆய்வு: c-யில் ஏதேனும் தெரியும் சேதம் உள்ளதா என அவ்வப்போது சரிபார்க்கவும்.asing or wiring. If any damage is found, disconnect power and consult a qualified electrician.
  • சுற்றுச்சூழல் நிலைமைகள்: Ensure the operating environment remains within the specified indoor conditions (IP20).

8. சரிசெய்தல்

பிரச்சனைசாத்தியமான காரணம்தீர்வு
ஒளி இயக்கவில்லை.
  • மின்சாரம் இல்லை.
  • LUX setting is too low (set for darkness).
  • Detection range (SENS) is too low.
  • தவறான வயரிங்.
  • No movement within detection area.
  • மின் இணைப்பைச் சரிபார்க்கவும்.
  • Adjust LUX setting towards the sun icon.
  • Increase SENS setting.
  • வயரிங் இணைப்புகளைச் சரிபார்க்கவும் (முதலில் பவரை ஆஃப் செய்யவும்).
  • Test by moving within the sensor's range.
ஒளி தொடர்ந்து எரிந்து கொண்டே இருக்கும்.
  • Continuous movement detected.
  • SENS setting is too high, detecting through walls.
  • TIME அமைப்பு மிக நீளமாக உள்ளது.
  • பழுதடைந்த அலகு.
  • Ensure no constant movement in the area.
  • Decrease SENS setting.
  • Decrease TIME setting.
  • சிக்கல்கள் தொடர்ந்தால், வாடிக்கையாளர் ஆதரவைத் தொடர்புகொள்ளவும்.
Light turns on unexpectedly.
  • SENS setting is too high.
  • Interference from external sources (e.g., strong electromagnetic fields, large moving objects outside the intended area).
  • Decrease SENS setting.
  • Relocate the detector if possible, or adjust SENS to minimize interference.

9. உத்தரவாதம் மற்றும் ஆதரவு

SEBSON products are manufactured with quality and reliability in mind. For specific warranty details, please refer to the documentation provided at the time of purchase or visit the official SEBSON website. If you encounter any issues or require technical assistance, please contact SEBSON customer support through their official channels.

மேலும் தகவலுக்கு, செல்க: www.sebson.de

தொடர்புடைய ஆவணங்கள் - 2_X_HF_CEIL_A

முன்view SEBSON IR_OUT_A/AA Infrared Motion Detector - Installation and User Manual
Comprehensive user manual and installation guide for the SEBSON IR_OUT_A and IR_OUT_AA infrared motion detector. Covers features, safety, installation, wiring, adjustments, technical data, and WEEE information.
முன்view SEBSON IR மோஷன் டிடெக்டர் (IR_ES_G / IR_ES_GA) நிறுவல் மற்றும் பயனர் கையேடு
பாதுகாப்பு வழிமுறைகள், தொழில்நுட்ப விவரக்குறிப்புகள், கண்டறிதல் வரம்பு மற்றும் WEEE அகற்றல் தகவல் உள்ளிட்ட SEBSON IR மோஷன் டிடெக்டரை (IR_ES_G / IR_ES_GA) நிறுவுவதற்கும் பயன்படுத்துவதற்கும் விரிவான வழிகாட்டி.
முன்view SEBSON IR Motion Detector IR_WAL_E: User Manual and Installation Guide
Comprehensive user manual and installation guide for the SEBSON IR_WAL_E infrared motion detector. Learn about its features, safety precautions, installation steps, technical specifications, and proper disposal.
முன்view SEBSON IR WAL C Motion Detector: Installation Guide, Features, and Technical Specifications
Comprehensive guide for the SEBSON IR WAL C infrared motion detector. Learn about its intended use, safety precautions, installation steps, operational features, technical data, and disposal information.
முன்view SEBSON IR_WAL_F Motion Detector: User Manual and Installation Guide
Comprehensive guide for the SEBSON IR_WAL_F infrared motion detector, covering intended use, safety instructions, installation, technical specifications, and disposal information.
முன்view SEBSON IR_ESO_F அகச்சிவப்பு மோஷன் டிடெக்டர் நிறுவல் மற்றும் பயனர் கையேடு
SEBSON IR_ESO_F அகச்சிவப்பு இயக்கக் கண்டறிதலுக்கான விரிவான வழிகாட்டி, நிறுவல், செயல்பாடு, பாதுகாப்பு மற்றும் தொழில்நுட்ப விவரக்குறிப்புகளை உள்ளடக்கியது. லைட்டிங் கட்டுப்பாட்டிற்கு இந்த இயக்கக் கண்டறிதலை எவ்வாறு திறம்பட பயன்படுத்துவது என்பதை அறிக.