Meross CS11

Meross CS11 காம்போ ஸ்மோக் மற்றும் கார்பன் மோனாக்சைடு அலாரம் பயனர் கையேடு

Model: CS11 | Brand: Meross

1. அறிமுகம்

This user manual provides comprehensive instructions for the installation, operation, and maintenance of your Meross CS11 Combo Smoke and Carbon Monoxide Alarm. Please read this manual thoroughly before installation and keep it for future reference. This device is designed to detect both smoke and carbon monoxide (CO) to enhance your home safety.

The Meross CS11 alarm complies with European standards EN 14604 for smoke alarms and EN 50291 for carbon monoxide alarms.

2. தயாரிப்பு அம்சங்கள்

  • இரட்டை சென்சார் தொழில்நுட்பம்: Combines a photoelectric smoke sensor and an electrochemical carbon monoxide sensor for comprehensive protection.
  • 10 வருட பேட்டரி ஆயுள்: Equipped with a sealed 3V lithium battery designed to last for 10 years, providing continuous protection without battery replacement.
  • Loud 85 dB Alarm: Emits a powerful 85-decibel alarm at 3 meters to alert occupants effectively in case of an emergency.
  • சோதனை/அமைதி பொத்தான்: Allows for easy testing of the alarm's functionality and silencing false alarms.
  • Tri-Color LED Indicator: Provides clear visual status indications for normal operation (green), fault/low battery/end-of-life (amber), and alarm/test/silence (red).
  • Automatic Self-Verification: The device performs regular self-checks to ensure proper functioning.
  • எளிதான நிறுவல்: Comes with a mounting bracket and screws for quick and simple ceiling or wall installation.
  • Wide Detection Area: Detects carbon monoxide over an area of up to 40 square meters.

3. தொகுப்பு உள்ளடக்கங்கள்

பிரித்தெடுத்தவுடன், கீழே பட்டியலிடப்பட்டுள்ள அனைத்து பொருட்களும் உள்ளனவா மற்றும் நல்ல நிலையில் உள்ளனவா என்பதை சரிபார்க்கவும்:

  • 1 x Meross CS11 Combo Smoke and Carbon Monoxide Alarm
  • 1 x பெருகிவரும் அடைப்புக்குறி
  • 2 x திருகுகள்
  • 1 x பயனர் கையேடு

4. பாதுகாப்பு தகவல்

Please read and understand all safety instructions before installing and operating the alarm. Failure to follow these instructions may result in property damage, injury, or death.

  • This alarm is designed for indoor use only.
  • Do not paint the alarm. Paint can clog the sensor openings and interfere with the alarm's ability to detect smoke or CO.
  • Do not install in areas with high humidity, extreme temperatures, or excessive dust.
  • Test the alarm monthly and after any battery change or relocation.
  • The 10-year battery is sealed and non-replaceable. Do not attempt to open the unit or replace the battery.
  • This device is not intended to replace proper installation and maintenance of fuel-burning appliances, nor the ventilation systems of these appliances.
  • Carbon monoxide is invisible, odorless, and tasteless. This alarm is designed to detect CO gas from any source of combustion.

5. அமைவு மற்றும் நிறுவல்

Proper placement and installation are crucial for the effective operation of your Meross CS11 alarm.

5.1 Recommended Locations

  • Install at least one alarm on every level of your home, including basements.
  • Place alarms in hallways outside of sleeping areas.
  • For best CO detection, install an alarm in or near rooms where fuel-burning appliances are located.
  • For best smoke detection, install in the center of the ceiling. If ceiling installation is not possible, install on a wall, at least 10-30 cm (4-12 inches) from the ceiling.

5.2 தவிர்க்க வேண்டிய இடங்கள்

  • Within 1 meter (3 feet) of cooking appliances, heating vents, or ceiling fans.
  • In extremely dusty, dirty, or greasy areas.
  • நேரடி சூரிய ஒளி அல்லது தீவிர வெப்பநிலை ஏற்ற இறக்கங்கள் உள்ள பகுதிகளில்.
  • In areas with high humidity, such as bathrooms.

5.3 நிறுவல் படிகள்

  1. மவுண்டிங் இடத்தை தயார் செய்யவும்: Choose a suitable location according to the guidelines above.
  2. மவுண்டிங் பிராக்கெட்டை இணைக்கவும்: Use the provided screws to securely attach the mounting bracket to the ceiling or wall.
  3. அலாரத்தை ஏற்றவும்: Align the alarm with the mounting bracket and twist clockwise until it clicks into place. The alarm will automatically activate upon proper installation.
  4. அலாரத்தை சோதிக்கவும்: After installation, press and hold the Test/Silence button for a few seconds to ensure the alarm sounds. Refer to the "Operating Instructions" section for more details on testing.
Image showing a person installing the Meross CS11 alarm on a ceiling.

Figure 5.3.1: Easy Installation of the Meross CS11 Alarm. The image depicts a person on a ladder installing the alarm on a ceiling, with an inset showing the mounting bracket and screws.

6. இயக்க வழிமுறைகள்

6.1 LED காட்டி நிலை

Image showing the tri-color LED indications for the Meross CS11 alarm: Green for Standby, Amber for Fault/Low Battery/End of Life, Red for Alarm/Test/Silence.

Figure 6.1.1: Tri-color LED Indication. This image illustrates the different LED colors and their corresponding alarm statuses.

  • பச்சை எல்.ஈ.டி: Flashes once every 60 seconds – Indicates normal operation (Standby).
  • ஆம்பர் LED: Flashes once every 60 seconds with a chirp – Indicates a fault, low battery, or end-of-life.
  • சிவப்பு எல்.ஈ.டி: Flashes rapidly with loud alarm – Indicates smoke or CO detection (Alarm).
  • சிவப்பு எல்.ஈ.டி: Flashes during test or silence mode.

6.2 அலாரத்தைச் சோதித்தல்

It is recommended to test your alarm monthly to ensure it is functioning correctly.

  1. Press and hold the Test/Silence button located on the front of the alarm.
  2. The alarm will emit a series of loud beeps, and the red LED will flash. This indicates the alarm is working.
  3. Release the button. The alarm will return to normal operation.
Image showing the Meross CS11 alarm emitting an 85dB sound wave, indicating a loud buzzer alarm.

Figure 6.2.1: Loud Buzzer Alarm. This image visually represents the 85dB alarm sound emitted by the device.

6.3 Silencing the Alarm

In case of a non-emergency alarm (e.g., cooking smoke), you can temporarily silence the alarm:

  • Press the Test/Silence button once.
  • The alarm will enter a temporary silence period (typically 5-10 minutes). The red LED will continue to flash during this period.
  • If the smoke or CO concentration remains high after the silence period, the alarm will reactivate.

Warning: Do not silence the alarm without first investigating the cause of the alarm. If the cause is unknown, evacuate the premises immediately.

7. பராமரிப்பு

Regular maintenance ensures the longevity and reliability of your Meross CS11 alarm.

  • மாதாந்திர சோதனை: Test the alarm monthly using the Test/Silence button.
  • சுத்தம்: Gently vacuum the alarm cover once a month using a soft brush attachment to remove dust and debris. Do not use cleaning agents or solvents.
  • பேட்டரி: The battery is sealed and designed for 10 years of operation. Do not attempt to replace it. When the battery is low or the unit reaches its end-of-life, the amber LED will flash with a chirp. Replace the entire unit.

8. சரிசெய்தல்

பிரச்சனைசாத்தியமான காரணம்தீர்வு
Alarm chirps every 60 seconds (Amber LED).Low battery, fault, or end-of-life.The battery is sealed. If the alarm is chirping, it indicates the unit needs to be replaced.
Alarm sounds frequently without apparent smoke/CO.False alarm due to cooking fumes, steam, dust, or improper placement.Press the Test/Silence button. Relocate the alarm if false alarms persist due to environmental factors. Clean the alarm.
சோதனையின் போது அலாரம் ஒலிக்கவில்லை.Unit not activated, battery depleted, or unit malfunction.Ensure the alarm is properly mounted and activated. If it still doesn't work, the unit may be faulty and needs replacement.
Green LED not flashing.Unit not activated or malfunction.Ensure the alarm is properly mounted and activated. If the issue persists, the unit may be faulty and needs replacement.

9. விவரக்குறிப்புகள்

மாதிரி எண்CS11
சக்தி ஆதாரம்Sealed 3V Lithium Battery (non-replaceable, 10-year life)
சென்சார் வகைPhotoelectric (Smoke), Electrochemical (CO)
எச்சரிக்கை சத்தம்≥ 85 dB at 3 meters
CO கண்டறிதல் வரம்பு40 m² வரை
இயக்க வெப்பநிலை0°C முதல் 40°C வரை (32°F முதல் 104°F வரை)
இயக்க ஈரப்பதம்≤ 95% RH (ஒடுக்காதது)
பரிமாணங்கள் (விட்டம் x உயரம்)120 mm x 28 mm (approx. 4.72 in x 1.1 in)
எடை135 கிராம் (தோராயமாக 4.76 அவுன்ஸ்)
சான்றிதழ்கள்EN 14604:2005/AC:2008 (Smoke), EN 50291-1:2010 (CO)
பொருள்ஏபிஎஸ்
Image showing the Meross CS11 alarm with labels pointing to its components: Smoke/CO Entrance, Test/Silence Button, LED Indicator, Buzzer. An inset shows its compact dimensions (12 cm diameter, 2.8 cm thickness).

Figure 9.1.1: Elegant and Compact Design with Component Overview. This image highlights the key external features and dimensions of the alarm.

10. உத்தரவாதத் தகவல்

Specific warranty details are not provided in the product information. Please refer to the official Meross website or contact Meross customer support for detailed warranty terms and conditions applicable to your region.

11. வாடிக்கையாளர் ஆதரவு

For technical assistance, troubleshooting, or general inquiries, please visit the official Meross support page or contact their customer service. Contact information can typically be found on the Meross webதளத்தில் அல்லது தயாரிப்பு பேக்கேஜிங்கில்.

நீங்கள் பார்வையிடலாம் Meross Brand Store on Amazon மேலும் தயாரிப்பு தகவலுக்கு.

தொடர்புடைய ஆவணங்கள் - CS11

முன்view Meross CS11 Smoke and Carbon Monoxide Alarm User Manual
This user manual for the Meross CS11 Combo Smoke and Carbon Monoxide Alarm provides comprehensive guidance on installation, operation, safety features, and maintenance for reliable home protection against fire and CO hazards.
முன்view Meross CS11 Smoke and Carbon Monoxide Combination Alarm User Manual
User manual for the Meross CS11 combination smoke and carbon monoxide alarm. Provides detailed information on product specifications, installation, operation, maintenance, troubleshooting, and safety guidelines.
முன்view Meross GS883-A காம்பினேஷன் ஸ்மோக்/CO அலாரம் பயனர் கையேடு
இந்த அத்தியாவசிய வீட்டுப் பாதுகாப்பு சாதனத்திற்கான பாதுகாப்பு, நிறுவல், செயல்பாடு, பராமரிப்பு மற்றும் உத்தரவாதத் தகவல்களை விவரிக்கும் Meross GS883-A Combination Smoke/CO அலாரத்திற்கான பயனர் கையேடு.
முன்view Meross GS883-A Combination Smoke and Carbon Monoxide Alarm User Manual
Comprehensive user manual for the Meross GS883-A Combination Smoke and Carbon Monoxide Alarm, covering installation, operation, safety, troubleshooting, and specifications.
முன்view Meross GS883-A Smoke and Carbon Monoxide Alarm User Manual
User manual for the Meross GS883-A Combination Smoke/CO alarm, providing essential information on installation, operation, safety, and maintenance for effective fire and carbon monoxide detection.
முன்view Meross MA151/MA152 Smart Smoke Alarm User Manual | Installation & Safety Guide
This comprehensive user manual for the Meross MA151 and MA152 smart smoke alarms details safety features, product specifications, package contents, step-by-step installation, hub pairing, recommended placement, and alert rules for optimal home fire safety.