This user manual provides essential information for the safe and efficient installation, operation, and maintenance of your SFA Sanicondens Clim mini S condensate pump. Please read these instructions carefully before installation and keep them for future reference. This pump is designed to remove condensate from air conditioning units with a capacity of up to 8 kW (27,000 BTU).
பாதுகாப்பு தகவல்
- Always disconnect the power supply before performing any installation, maintenance, or repair work.
- Installation should be performed by a qualified professional in accordance with local electrical and plumbing codes.
- Do not operate the pump if it is damaged or if any electrical components are exposed.
- Ensure the pump is installed in a location where it is protected from freezing temperatures.
- This pump is designed for condensate removal from air conditioning units only. Do not use it for other liquids or applications.
அமைவு மற்றும் நிறுவல்
The SFA Sanicondens Clim mini S pump is designed for discreet installation, typically within the air conditioning unit or a nearby conduit. Follow these steps for proper setup:
1. பேக்கிங் மற்றும் ஆய்வு
Carefully remove all components from the packaging. Inspect the pump and accessories for any signs of damage. Do not install if damaged.

படம் 1: The SFA Sanicondens Clim mini S condensate pump (left) and its separate reservoir (right).
2. Component Identification and Dimensions
Familiarize yourself with the pump components and their dimensions to ensure proper fit and installation space.

படம் 2: Technical drawing showing the dimensions of the pump and reservoir unit in millimeters.
3. Placement and Connection
The pump consists of two main parts: the detection unit (reservoir) and the pump unit. The detection unit should be placed to collect condensate directly from the air conditioning unit's drain pan. The pump unit can be installed remotely, connected to the detection unit via a small tube and electrical cable.

படம் 3: Installation diagram. (A) Air conditioner drain, (B) Detection unit, (C) Pump unit, (D) Check valve, (E) Discharge pipe leading to drain.
- Connect the condensate drain hose from the air conditioning unit to the inlet of the detection unit.
- Connect the small tube and electrical cable from the detection unit to the pump unit.
- Attach the discharge pipe to the pump unit's outlet. Ensure a check valve is installed to prevent backflow.
- Route the discharge pipe to a suitable drain point, ensuring it has a continuous downward slope after reaching its maximum lift height. The pump can lift water up to 78.74 inches (approximately 2 meters).
- Connect the pump to a 230 Volt electrical supply.

படம் 4: Example of a discreet installation of the SFA Sanicondens Clim mini S pump with an air conditioning unit.
இயக்க வழிமுறைகள்
The SFA Sanicondens Clim mini S condensate pump operates automatically. Once properly installed and connected to power, it will activate when the condensate level in the detection unit reaches a predetermined level, pumping the water away. It will then switch off once the level drops.
- பம்ப் இயங்குவதற்கு ஏர் கண்டிஷனிங் யூனிட் கண்டன்சேட்டை உற்பத்தி செய்வதை உறுதி செய்யவும்.
- Listen for the pump's operation. It is designed to be quiet (21 dB).
- அதிகபட்ச ஓட்ட விகிதம் ஒரு மணி நேரத்திற்கு 9 லிட்டர்.

படம் 5: Pump performance curve showing head (H in meters) versus flow rate (Q in L/h). The solid line indicates typical operating range.
பராமரிப்பு
Regular maintenance ensures the longevity and efficient operation of your condensate pump.
- வருடாந்திர சுத்தம் செய்தல்: At least once a year, clean the filter screen in the detection unit to prevent blockages.
- ஆய்வு: Periodically check all connections for leaks and ensure the discharge pipe is free from kinks or obstructions.
- மின் துண்டிப்பு: Always disconnect the pump from the power supply before performing any cleaning or inspection.
சரிசெய்தல்
If you encounter issues with your SFA Sanicondens Clim mini S pump, refer to the following common problems and solutions:
| பிரச்சனை | சாத்தியமான காரணம் | தீர்வு |
|---|---|---|
| பம்ப் தொடங்கவில்லை | No power; float switch stuck; clogged inlet. | Check power supply; inspect float for free movement; clean inlet and filter screen. |
| பம்ப் தொடர்ந்து இயங்குகிறது | Float switch stuck; discharge pipe blocked or kinked; check valve faulty. | Inspect float; clear discharge pipe; check check valve for proper function. |
| நீர் கசிவு | Loose connections; damaged hose/pipe. | Tighten all connections; replace damaged components. |
| அதிக சத்தம் | Vibrations; air in the system; pump not securely mounted. | Ensure secure mounting; bleed air from system if possible; check for obstructions. |
இந்த தீர்வுகளை முயற்சித்த பிறகும் சிக்கல் தொடர்ந்தால், தகுதிவாய்ந்த சேவை ஊழியர்களைத் தொடர்பு கொள்ளவும்.
விவரக்குறிப்புகள்
| அம்சம் | விவரம் |
|---|---|
| மாதிரி எண் | CLIMMINI3S |
| பிராண்ட் | இந்த SFA |
| அதிகபட்ச ஓட்ட விகிதம் | மணிக்கு 9 லிட்டர் (லிட்டர்/ம) |
| அதிகபட்ச லிஃப்ட் உயரம் | 78.74 அங்குலம் (தோராயமாக 2 மீட்டர்) |
| சக்தி ஆதாரம் | மின்சார கேபிள் |
| தொகுதிtage | 230 வோல்ட் |
| மின்சார சக்தி | 22 வாட்ஸ் |
| ஒலி நிலை | 21 டெசிபல்கள் (dB) |
| Dimensions (Pump Unit) | 10.5 x 3.2 x 5.4 செ.மீ (தோராயமாக 4.1 x 1.3 x 2.1 அங்குலம்) |
| எடை | 390 கிராம் (தோராயமாக 0.86 பவுண்ட்) |
| பொருள் | பிளாஸ்டிக் |
| Suitable for AC units up to | 8 kW / 27,000 BTU |
உத்தரவாத தகவல்
SFA products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official SFA webஉத்தரவாதக் கோரிக்கைகளுக்கு உங்கள் வாங்கியதற்கான ஆதாரத்தை வைத்திருங்கள்.
வாடிக்கையாளர் ஆதரவு
For technical assistance, spare parts, or service inquiries, please contact SFA customer support or your local distributor. Contact information can typically be found on the SFA official webதளம் அல்லது தயாரிப்பு பேக்கேஜிங்கில்.