This manual provides essential information for the installation, operation, and maintenance of the DewertOKIN ZYT-36S-42 massage motor. This motor is designed as a direct replacement for existing OKIN massage motors in adjustable bed bases, specifically for head or feet massage functions. It is crucial to verify compatibility, particularly the connector type, before installation.

முக்கியமான பாதுகாப்பு தகவல்

தயாரிப்பு முடிந்துவிட்டதுview

The ZYT-36S-42 is a compact DC massage motor designed for adjustable bed bases. It features a durable black casing, an integrated power cable, and a specific connector for easy integration into compatible systems. This motor is interchangeable and can be used to replace either the head or feet massage motor in your adjustable bed.

DewertOKIN ZYT-36S-42 massage motor with cable and connector

படம் 1: The DewertOKIN ZYT-36S-42 massage motor, showing its cylindrical body, attached power cable, and white two-pin connector. This is the complete unit as it appears out of the packaging.

பக்கம் view of DewertOKIN ZYT-36S-42 massage motor with specification label

படம் 2: ஒரு பக்கம் view of the ZYT-36S-42 massage motor, highlighting the product label. The label displays key specifications such as "DC MOTOR", "ZYT-36S-42", "24V", and "2500RPM ±10%".

Close-up of the two-pin connector on the ZYT-36S-42 massage motor cable

படம் 3: A detailed close-up of the white two-pin connector attached to the motor's power cable. This connector type is critical for ensuring compatibility with your adjustable bed base's wiring harness.

நிறுவல் வழிகாட்டி

Follow these steps carefully to replace your adjustable bed's massage motor. Ensure you have the correct replacement motor by checking the connector type before proceeding.

  1. Prepare the Bed: Unplug the adjustable bed base from the wall outlet to completely cut off power.
  2. இருக்கும் மோட்டாரைக் கண்டறியவும்: Identify the massage motor you intend to replace. This will typically be located near the head or foot section of the bed frame, often secured with screws or clips.
  3. பழைய மோட்டாரைத் துண்டிக்கவும்: Carefully disconnect the power cable of the old motor from the bed's wiring harness. Note how it is connected.
  4. பழைய மோட்டாரை அகற்று: Unscrew or unclip the old motor from its mounting bracket on the bed frame.
  5. புதிய மோட்டாரை நிறுவுதல்: Position the new DewertOKIN ZYT-36S-42 motor into the mounting bracket. Secure it firmly using the original screws or clips.
  6. புதிய மோட்டாரை இணைக்கவும்: Connect the new motor's two-pin connector to the corresponding port on the bed's wiring harness. Ensure a snug and secure fit.
  7. சோதனை செயல்பாடு: Once the motor is securely installed and connected, plug the adjustable bed base back into the power outlet. Test the massage function to ensure the new motor operates correctly.
  8. கேபிள் மேலாண்மை: Route the motor's cable neatly and secure it to prevent it from being pinched or tangled during bed operation.

Note: This motor is interchangeable and can be used for either the head or feet massage function.

இயக்க வழிமுறைகள்

The DewertOKIN ZYT-36S-42 massage motor operates as an integral component of your adjustable bed base. It does not have independent controls. Its function is controlled directly by the bed's remote control or integrated control panel.

பராமரிப்பு

The ZYT-36S-42 massage motor is designed for minimal maintenance. Regular inspection can help ensure its longevity and proper function.

சரிசெய்தல்

If you experience issues with your DewertOKIN ZYT-36S-42 massage motor, consult the table below for common problems and their potential solutions.

பிரச்சனைசாத்தியமான காரணம்தீர்வு
Motor does not vibrate or is unresponsive.
  • Bed not plugged in.
  • Loose or disconnected motor cable.
  • Faulty bed remote or control unit.
  • பழுதடைந்த மோட்டார்.
  • Ensure the bed base is securely plugged into a working power outlet.
  • Check that the motor's connector is firmly seated in the bed's wiring harness.
  • Test other functions of the bed. If other functions also fail, the issue may be with the bed's power supply or control unit.
  • If all connections are secure and the bed's control unit is functional, the motor may be faulty and require replacement.
Weak or inconsistent vibration.
  • Partial connection of motor cable.
  • Obstruction around the motor.
  • Motor nearing end of life.
  • Unplug the bed, then firmly re-seat the motor's connector.
  • Check for any objects (bedding, wires) that might be dampening the vibration.
  • If the motor is old, its performance may degrade over time.
Unusual noises from the motor.
  • தளர்வான மவுண்டிங்.
  • Internal motor issue.
  • Ensure the motor is securely fastened to its mounting bracket.
  • If the noise persists and the motor is new, it may indicate a manufacturing defect. If old, it may be failing.

சரிசெய்தல் படிகள் சிக்கலை தீர்க்கவில்லை என்றால், வாடிக்கையாளர் ஆதரவைத் தொடர்பு கொள்ளவும்.

தொழில்நுட்ப விவரக்குறிப்புகள்

விவரக்குறிப்புவிவரம்
மாதிரி எண்ZYT-36S-42
வகைDC Massage Motor
தொகுதிtage24V
மதிப்பிடப்பட்ட RPM2500 RPM ±10%
இணக்கத்தன்மைReplaces OKIN branded massage motors only. Interchangeable for head or feet massage.
இணைப்பான் வகைTwo-pin (as shown in Figure 3)

உத்தரவாத தகவல்

Specific warranty terms for the DewertOKIN ZYT-36S-42 massage motor are typically provided by the seller at the time of purchase. Please refer to your original purchase documentation or contact the seller directly for detailed warranty coverage, duration, and claim procedures.

For purchases made from "Irvine Home Collection USA", please consult their specific return and warranty policies.

வாடிக்கையாளர் ஆதரவு

If you have questions or require further assistance with your DewertOKIN ZYT-36S-42 massage motor, please contact the seller from whom you purchased the product. When contacting support, please have your purchase details and the product's ASIN (B0DNRSX673) readily available for faster service.

For general inquiries about DewertOKIN products, you may also visit the official DewertOKIN webதளம்.

தொடர்புடைய ஆவணங்கள் - ZYT-36S-42

முன்view DewertOkin OKIMAT 4 Series Installation Manual
Installation manual for DewertOkin OKIMAT 4 series electric bed actuators (IPS, IPSe, EPS, EPSe), detailing mounting, safety, technical specifications, and troubleshooting for adjustable bed systems.
முன்view RF48 ரிமோட் கண்ட்ரோல் பயனர் கையேடு - DewertOkin
DewertOkin RF48 ரிமோட் கண்ட்ரோலுக்கான பயனர் கையேடு, அதன் செயல்பாடுகள், முறைகள் மற்றும் மசாஜ் மற்றும் சிறப்பு நிலை கட்டுப்பாடுகள் உட்பட சரிசெய்யக்கூடிய படுக்கைகளுக்கான செயல்பாட்டை விவரிக்கிறது.
முன்view DewertOkin Motion Assist / Motion Assist Pro Control Keypad User Manual
This manual provides a functional description, installation guide, operating instructions, troubleshooting tips, and maintenance information for the DewertOkin Motion Assist and Motion Assist Pro control keypads, used with OKIN drive systems for height-adjustable tables.
முன்view OKIMAT 4 Installation Instructions: IPS, IPSe, EPS, EPSe Actuator Systems
Detailed installation instructions for DewertOkin's OKIMAT 4 series electric actuators (IPS, IPSe, EPS, EPSe), designed for adjustable bed mechanisms. Learn about proper setup, safety, and technical specifications.
முன்view OKIMAT 4 Installation Instructions for IPS, IPSe, EPS, EPSe Drives
Detailed installation instructions for DewertOkin's OKIMAT 4 series drives (IPS, IPSe, EPS, EPSe). Covers safety guidelines, component descriptions, technical specifications, installation procedures, and troubleshooting for integrating these electric drives into end products like beds.
முன்view DUOMAT 9 Installation Instructions - DewertOkin
Comprehensive installation guide for the DewertOkin DUOMAT 9 electric drive system, detailing setup, safety protocols, technical specifications, and troubleshooting for manufacturers of adjustable furniture and medical equipment.