1. அறிமுகம்
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the VEICHI AC10 series frequency converters. Please read this manual thoroughly before using the product to ensure proper handling and to prevent damage or injury.
The VEICHI AC10 series frequency converters are designed for general-purpose applications, offering reliable motor control and energy efficiency. This manual covers models such as AC10-T/S2-R75G-B-220V, AC10-T/S2-1R5G-B-220V, AC10-T/S2-2R2G-B-220V, AC10-T3-R75G-B-380V, and AC10-T3-1R5G-B-380V.
2. பாதுகாப்பு முன்னெச்சரிக்கைகள்
Always observe the following safety precautions to prevent electric shock, fire, or personal injury. Failure to comply may result in severe consequences.
- தகுதியான பணியாளர்கள்: Installation, wiring, operation, and maintenance must be performed by qualified electrical personnel only.
- மின் துண்டிப்பு: Always disconnect all power sources before performing any wiring or maintenance. Wait at least 5 minutes after power off for the capacitor discharge indicator to extinguish.
- அடிப்படை: Ensure the frequency converter is properly grounded according to local electrical codes.
- சுற்றுச்சூழல் நிலைமைகள்: Do not operate the converter in environments exceeding specified temperature, humidity, or dust levels.
- பாதுகாப்பு கவர்கள்: Do not remove protective covers or touch internal components while power is applied.
3. தயாரிப்பு முடிந்துவிட்டதுview
The VEICHI AC10 series frequency converter features a compact design with an integrated control panel for easy operation and monitoring.

படம் 3.1: முன் view of the VEICHI AC10 Frequency Converter. This image displays the main unit, highlighting the digital display for parameters, control buttons for programming and operation, and the various terminal blocks for power and control wiring. A screwdriver is visible in the side compartment.
3.1. Control Panel Layout
The control panel consists of a digital display and several function buttons:
- காட்சி: Shows operational parameters, fault codes, and programming values.
- PRG (திட்டம்): அளவுரு அமைப்பு பயன்முறையில் நுழைகிறது/வெளியேறுகிறது.
- மேல்/கீழ் அம்புகள்: Navigate through parameters, adjust values.
- ஓடு: மோட்டாரைத் தொடங்குகிறது.
- நிறுத்து/மீட்டமை: Stops the motor, resets fault conditions.
- SET/SHIFT: Confirms parameter settings, shifts cursor during input.
4. அமைவு மற்றும் நிறுவல்
4.1 மவுண்டிங்
Mount the frequency converter vertically on a flat, non-flammable surface. Ensure adequate ventilation space around the unit (at least 10 cm above and below, 5 cm on sides) for heat dissipation.
4.2. வயரிங்
Refer to the wiring diagram provided with your specific model for detailed connections. General wiring guidelines:
- Power Input (R, S, T or L1, L2): Connect to the main power supply. Ensure correct voltage (220V or 380V depending on model).
- மோட்டார் வெளியீடு (U, V, W): Connect to the motor terminals.
- தரை (PE): Connect to a reliable ground point.
- கட்டுப்பாட்டு முனையங்கள்: For external control signals (e.g., start/stop, speed reference, fault output).
Warning: Incorrect wiring can lead to severe damage to the unit or personal injury. Consult a qualified electrician if unsure.
5. இயக்க வழிமுறைகள்
5.1. ஆரம்ப பவர்-அப்
- After completing all wiring, apply power to the frequency converter.
- The display will light up, typically showing "0.00" or a default frequency.
5.2. Basic Operation (Keypad Control)
- அதிர்வெண் அமைக்கவும்: அழுத்தவும் PRG button to enter parameter mode. Navigate to the frequency setting parameter (e.g., F0.01) using the மேல்/கீழ் அம்புகள். அச்சகம் SET/SHIFT to edit, adjust value, then SET/SHIFT again to confirm. Press PRG வெளியேற வேண்டும்.
- மோட்டாரைத் தொடங்கு: அழுத்தவும் இயக்கவும் button. The motor will accelerate to the set frequency.
- மோட்டார் நிறுத்து: அழுத்தவும் நிறுத்து/மீட்டமை பொத்தான். மோட்டார் வேகத்தைக் குறைத்து நின்றுவிடும்.
5.3. அளவுரு அமைப்புகள்
The AC10 series has a comprehensive set of parameters for various functions. Refer to the detailed parameter list in the full product manual for advanced configurations (e.g., acceleration/deceleration times, motor parameters, control modes).
Example அளவுருக்கள்:
- F0.00: Run command source (keypad, terminal, communication)
- F0.01: Frequency setting source (keypad, analog input, communication)
- F0.03: அதிகபட்ச வெளியீடு அதிர்வெண்
- F0.04: முடுக்கம் நேரம்
- F0.05: குறைப்பு நேரம்
6. பராமரிப்பு
Regular maintenance ensures the longevity and reliable operation of your frequency converter.
- சுத்தம்: Periodically clean the cooling fins and fan to prevent dust accumulation, which can hinder heat dissipation. Use compressed air or a soft brush. Ensure power is off before cleaning.
- முனையச் சரிபார்ப்பு: Annually check all wiring terminals for tightness. Loose connections can cause overheating or intermittent operation.
- சுற்றுச்சூழல் சோதனை: Verify that the operating environment remains within specified temperature and humidity ranges.
- Fan Replacement: Cooling fans have a limited lifespan. Consider replacing them every 3-5 years, depending on operating conditions, to maintain optimal cooling.
7. சரிசெய்தல்
This section provides common issues and their potential solutions. For complex problems, contact technical support.
| Problem/Fault Code | சாத்தியமான காரணம் | தீர்வு |
|---|---|---|
| No Display/Power | No input power; Blown fuse; Internal fault. | Check power supply; Check fuses; Contact support. |
| Overcurrent (OC) Fault | Motor overload; Short circuit in motor wiring; Rapid acceleration/deceleration. | Check motor load; Inspect motor wiring; Increase acceleration/deceleration time. |
| ஓவர்வோல்tage (OV) Fault | உள்ளீடு தொகுதிtage too high; Rapid deceleration with high inertia load. | உள்ளீடு தொகுதியை சரிபார்க்கவும்tage; Increase deceleration time; Consider braking resistor. |
| அண்டர்வால்tage (UV) Fault | உள்ளீடு தொகுதிtage too low; Power supply dip. | உள்ளீடு தொகுதியை சரிபார்க்கவும்tage; Ensure stable power supply. |
| Overheat (OH) Fault | Ambient temperature too high; Fan failure; Blocked ventilation. | Improve ventilation; Clean cooling fins; Check fan operation. |
To reset a fault, press the நிறுத்து/மீட்டமை button after resolving the cause.
8. விவரக்குறிப்புகள்
The following specifications are typical for the VEICHI AC10 series. Specific values may vary slightly by model.
| அளவுரு | மதிப்பு/வரம்பு |
|---|---|
| உள்ளீடு தொகுதிtage | Single-phase 220V (AC10-T/S2 models) or Three-phase 380V (AC10-T3 models) |
| வெளியீட்டு அதிர்வெண் வரம்பு | 0.00 ஹெர்ட்ஸ் - 400.00 ஹெர்ட்ஸ் |
| கட்டுப்பாட்டு முறை | V/F control, Sensorless vector control |
| அதிக சுமை திறன் | 150% of rated current for 60 seconds |
| பாதுகாப்பு அம்சங்கள் | ஓவர் கரண்ட், ஓவர்வால்tagஇ, அண்டர்வால்tage, Overheat, Overload, Short circuit |
| இயக்க வெப்பநிலை | -10°C முதல் 40°C வரை (14°F முதல் 104°F வரை) |
| ஈரப்பதம் | Less than 90% RH (non-condensing) |
| பரிமாணங்கள் (தோராயமாக) | Varies by power rating (e.g., 2 x 2 x 2 inches for smaller models) |
| எடை (தோராயமாக) | Varies by power rating (e.g., 4.41 Pounds for smaller models) |
Note: For precise specifications of your specific model, refer to the product label or the comprehensive technical datasheet.
9. உத்தரவாதம் மற்றும் ஆதரவு
9.1. உத்தரவாதத் தகவல்
This product is typically covered by a manufacturer's warranty against defects in materials and workmanship for a period specified at the time of purchase. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by improper installation, misuse, unauthorized modification, or operation outside of specified environmental conditions.
For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact the seller.
9.2. தொழில்நுட்ப ஆதரவு
If you encounter issues that cannot be resolved using the troubleshooting guide, or require further technical assistance, please contact your supplier or the manufacturer's authorized service center.
ஆதரவைத் தொடர்பு கொள்ளும்போது, பின்வரும் தகவல்களை வழங்கத் தயாராக இருங்கள்:
- Product Model Number (e.g., AC10-T/S2-1R5G-B-220V)
- Serial Number (if applicable)
- வாங்கிய தேதி
- Detailed description of the problem, including any fault codes displayed.