Bionova-LOGO

Bionova IC10 20FR Auto Reader

Bionova-IC-20FR-Auto-Reader-PRODUCT

அம்சங்கள்

  1. பாதுகாப்பு உறை
  2. Incubation area for 12 SCBIs and 1 protein pen. Ampoule crusher.
  3. கட்டுப்பாட்டு குழு
  4. Positive indicator light (red)
  5. Negative indicator light (green)
  6. Incubation position number
  7. Incubation position number
  8. வெப்பநிலை தேர்வு பொத்தான்
  9. Alarm cancellation button
  10. Alarm cancellation button
  11. பிரிண்டர்
  12. Paper traction button
  13. காகிதத்திற்கான குழி
  14. USB போர்ட்
  15. Socket for power supply plug (12 Volts DC)
  16. Hole for external temperature control

பயன்பாட்டிற்கான வழிமுறைகள்

குறிப்பு: Remember to set the auto-reader local date and time before starting incubations.

Setting up your auto-reader
Place the auto-reader on a firm surface, free from vibrations, away from direct sunlight, hot or cold air flows, chemical, corrosive or flammable substances. Do not place the auto-reader in a way that would make it difficult to remove the power supply’s AC plug from mains. Leave a space of at least 10 cm from the auto-reader to the closest wall. Do not move the auto-reader periodically or during its use. Connect the auto-reader to a secure and stable electrical mains outlet socket. Do not wet or heat the device. If liquid is spilled on the auto-reader, disconnect and clean it. Before switching it on, check that all incubation positions are empty.

Using your auto-reader

  1. Switch on the auto-reader by connecting the power supply’s AC plug to the mains and then connect the plug at the other end of power supply to the rear of the auto-reader (See image 1).Bionova-IC-20FR-Auto-Reader (3)
  2. Set the auto-reader local date and time. For more information, please refer to the User Manual.Bionova-IC-20FR-Auto-Reader (4)
  3. Press and hold the temperature selection button for 3 seconds (See image 2). Press again to select the desired temperature. After 4 seconds, the temperature modification will automatically be accepted. Wait until the temperature & stability indicator light stops blinking.
  4. SCBI Incubation procedure
    • Select the appropriate incubation time for the incubation position you are planning to use. To select the incubation time for incubation positions 1 to 6, press the left incubation time selection button. To select the incubation time for incubation positions 7 to 12, press the right incubation time selection button (See image 3.A).Bionova-IC-20FR-Auto-Reader (5)
    • Place an SCBI in an incubation position. The reading process will start automatically after placing the SCBI (See image 3.B).Bionova-IC-20FR-Auto-Reader (6)
    • PRO1 Indicator Incubation procedure
    • To enable the PRO1 incubation position, press the following button for 1 second: 4.A).Bionova-IC-20FR-Auto-Reader (7)
    • Place the PRO1 indicator fully inside the PRO1 incubation position. Start the incubation and readout process by pressing the button: Bionova-IC-20FR-Auto-Reader (8)
  5. Wait until a readout result has been carried out. The positive or negative indicator light will turn on to indicate the result, and a ticket will be printed. For PRO1 indicators, the Auto-reader will inform the equivalent μg of protein quantity using a BSA (Bovine Serum Albumin) calibration curve. Do not remove the SCBI / PRO1 indicator once the reading process has begun. If this occurs, the results may be invalid.

குறிப்பு: To select a protein quantification threshold mode and a threshold value, please refer to the User Manual.
Disposal: Dispose of the SCBIs in accordance with your country’s waste-disposal guidelines.

இணைப்பு

  • To connect your auto-reader to a personal computer (PC) by USB, connect one end of the USB cable provided to the rear of the auto-reader and the other end to a USB port on your PC. Connect the auto-reader to a PC to use the
  • Bionova® Cloud Web Application. Please refer to the User Manual for more information.
  • Bionova® IC10/20FR Auto-reader incubation programs
  • The following incubation programs are available for your auto-reader.

Bionova® IC10/20FR Auto-reader incubation programs
The following incubation programs are available for your auto-reader.

Temperature Time Incubation Program

  • 60 ºC 20 minutes
  • 30 நிமிடங்கள்
  • 1 மணிநேரம்
  • 2 மணிநேரம்
  • 3 மணிநேரம்
  • PRO (7 minutes)
  • 20 minutes. at 60 °C
  • 30 minutes. at 60 °C
  • 1 hour at 60 °C
  • 2 °C வெப்பநிலையில் 60 மணிநேரம்
  • 3 °C வெப்பநிலையில் 60 மணிநேரம்
  • PRO at 60 °C
  • 37 °C 4 hours 4 hours at 37 °C

Bionova-IC-20FR-Auto-Reader (2)

குறிப்பு: Please read and follow the SCBI/ PRO1 indicator Instructions For Use before using it.

சின்னங்கள்

  • Bionova-IC-20FR-Auto-Reader (9)ஈரப்பதம் வரம்பு
  • Bionova-IC-20FR-Auto-Reader (10)வெப்பநிலை வரம்பு
  • Bionova-IC-20FR-Auto-Reader (11)எச்சரிக்கை
  • Bionova-IC-20FR-Auto-Reader (12)எச்சரிக்கை, சூடான மேற்பரப்பு
  • Bionova-IC-20FR-Auto-Reader (13)சி.இ.
  • Bionova-IC-20FR-Auto-Reader (14)நேரடி மின்னோட்டம்
  • Bionova-IC-20FR-Auto-Reader (15)உட்புற பயன்பாட்டிற்கு மட்டுமே
  • Bionova-IC-20FR-Auto-Reader (16)சூரிய ஒளியில் இருந்து விலகி இருங்கள்
  • Bionova-IC-20FR-Auto-Reader (17)தொகுதி குறியீடு
  • Bionova-IC-20FR-Auto-Reader (18)உற்பத்தியாளர்
  • Bionova-IC-20FR-Auto-Reader (20)Recycle electronic equipment
  • Bionova-IC-20FR-Auto-Reader (21)இயற்கை ரப்பர் லேடெக்ஸ் உள்ளது அல்லது இருப்பது

தயாரிப்பு விளக்கம்

The Bionova® IC10/20FR Auto-reader was designed for the incubation and automatic readout of Terragene® Bionova® Rapid, Super Rapid and Ultra Rapid Self-contained Biological Indicators (SCBIs) for sterilization and environmental disinfection process control applications, and for the incubation and automatic readout of Terragene® Chemdye® Hygiene Monitoring System Indicators (Protein pens) for cleaning control applications. The Bionova® IC10/20FR Auto-reader incubates at two different temperatures, 37 °C or 60 °C. The microorganisms within SCBIs vary depending on the sterilization process they were designed for; therefore, incubation temperatures and times differ accordingly. The Bionova® IC10/20FR Auto-reader allows two independent incubation time selections. One of them for incubation positions 1 to 6, and the other for incubation positions 7 to 12.
SCBIs designed for ethylene oxide (EO) sterilization are incubated at 37 ºC, while those used for monitoring other sterilization processes are incubated at 60 ºC.

குறிப்பு: Simultaneous incubation of SCBIs for monitoring EO processes along with SCBIs for monitoring other sterilization processes is not possible.
The Bionova® IC10/20FR Auto-reader detects positive and negative SCBIs easily and quickly, using advanced fluorescence techniques. A positive result can also be shown by a change in the culture medium color when extended incubations are carried out. Read the Instructions For Use of the SCBI for more information. The option to perform or not an extended incubation depends on the internal protocols of each laboratory or hospital. The Bionova® IC10/20FR Auto-reader generates a printed ticket each time an incubation program has been completed, enabling easy result management, for documentation compliance and safe-keeping.

பயன்பாட்டிற்கான அறிகுறிகள்

  • United States of America: Terragene® Bionova® IC10/20FR Reader Incubator incubates at 60 °C and reads the Terragene® Bionova® SCBI (BT220, BT221, BT222, and BT223) for fluorescent results at 30 minutes (BT223), 1 hour (BT221, BT222), and 3 hours (BT220).
  • Outside the United States of America: Terragene® Bionova® Reader Incubator IC10/20FR incubates at 60  °C and 37 °C, and read the Terragene® Bionova® SCBIs and the Terragene® Chemdye® Hygiene Monitoring System Indicators at the times prescribed in the User Manuals.

பாதுகாப்பு தகவல்

To avoid risks and/or damaging the device:

  • வீட்டிற்குள் மட்டுமே பயன்படுத்தவும்.
  • Do not place the auto-reader in a room exposed to direct sunlight or to high luminous intensity lamps. _Do not place the auto-reader near devices that emit strong electromagnetic fields.
  • Do not use the auto-reader on sloping surfaces or on surfaces that may be knocked, that may vibrate, be exposed to high temperatures, or high relative humidity.
  • சுத்தம் செய்வதற்கு முன் மின் கம்பியை துண்டிக்கவும்.
  • Do not use abrasive or corrosive cleaners or disinfectants.
  • Do not immerse into any liquid. Do not pour liquid into it.
  • Make sure the auto-reader is connected to an appropriate electrical mains outlet socket.
  • Use the included power supply (AC power adapter), power supply’s AC plug, power supply cords, and USB cable only. Check that all the items included are in good condition every day. If any of them is damaged, discontinue their use. The use of cables, adapters, cords, and/or power supplies different from the ones included may cause fires, electrical shocks, or even physical injuries.
  • Do not plug any devices into the auto-reader’s USB port other than devices compliant with IEC 60950-1, IEC 62368-1 or comparable, with safety extra-low voltages on its USB ports. Ask a qualified technician to check that the device is compatible. Attaching any other device to the USB port may damage the auto-reader and may not be safe for the user.
  • Do not attempt to repair the auto-reader yourself. This could lead to major and irreversible damage to the device. If the auto-reader malfunctions, contact your local distributor for further assistance.

To reduce the risk of using incompletely sterilized loads:

  • Please read, understand, and follow the Instructions For Use of each SCBI before incubating it.
  • Do not remove the SCBI before the auto-reader shows the final readout result.
  • Check that the spore carrier has been wetted completely by the culture medium.

To avoid the risk of injury by glass fragments produced when crushing the glass ampoule inside the SCBI tube:

  • Cool the SCBI during the indicated time before crushing the ampஓலே
  • Do not handle the SCBI excessively since this might cause the glass ampoule to explode.
  • Wear safety gloves and goggles when removing the SCBI from the sterilizer, pressing the SCBI’s cap, and crushing the SCBI’s ampஓலே
  • Do not use your finger to crush the SCBI. Use the ampoule crusher instead.

To avoid a potentially hazardous situation:

  • Avoid contact with the hot metal block inside each incubation position.
  • Do not insert your fingers or any other element, into the incubation positions.
  • Place only compatible SCBIs inside the incubation positions.

To avoid SCBIs from absorbing fluorescent particles:

  • Avoid direct contact between the SCBIs and chemical indicators or tapes before the SCBI incubation.
  • Avoid excessive SCBI handling that may lead to fingerprints or glove talc imprinted over the SCBI.
  • Note: Do not use this product in a manner not specified by Terragene S.A., otherwise the protection provided by the product might be affected.
  • Note: Only Terragene S.A. authorized personnel may access or service the internal components of the auto-reader. Parts or components inside the auto-reader should not be handled by the user.

இயக்க நிலைமைகள்

பவர் சப்ளை விவரக்குறிப்புகள்

Input parameters Operating conditions Units

  • தொகுதிtage range (100-240) AC Volts
  • Input parameters Operating conditions Units
  • Frequency 50-60 Hertz
  • தற்போதைய 1 Ampஈரெஸ்

Output parameters Values Units

  • தொகுதிtage 12 DC Volts
  • தற்போதைய 3 Ampஈரெஸ்
  • Terragene S.A. recommends using an Uninterruptible Power Supply (UPS) instead of voltagமின் நிலைப்படுத்திகள்.
  • since they fulfill two functions: they stabilize and maintain the energy during a power outage.

சுற்றுச்சூழல் இயக்க நிலைமைகள்

Environmental conditions Operating conditions Units

  • Altitude 3500 (maximum) Meters
  • Operation temperature 10-30 °Celsius
  • Relative humidity 30-80 %
  • Installation/Over-voltage Category II –
  • Pollution degree 2 –
  • Storage temperature 5-40 °Celsius
  • தொகுதிtage 12 DC Volts

Device safety compliance

The Bionova® IC10/20FR Auto-reader complies with the following standards and directives:

  • மின் பாதுகாப்பு IEC 61010-1
  • IEC 61010-2-010
  • குறைந்த தொகுதிtagமின் உத்தரவு 2014/35/EU
  • மின்காந்த இணக்கத்தன்மை (EMC) EN 61326-1
  • EMC உத்தரவு 2014/30/EU
  • ஐரோப்பிய ஆணையம் RoHS உத்தரவு 2011/65/EU
  • WEEE உத்தரவு 2012/19/EU

The Bionova® IC10/20FR Auto-reader does not represent photobiological risk and does not generate dangerous optical radiation used within its normal operating conditions, as per the requirements of IEC 62471 Standard.
Designed under Quality Management System standards ISO 13485:2016/EN ISO 13485:2016.

Note: The auto-reader has been evaluated for conformity for use in business environments. There may be concerns about radio interference if used in home environments. This applies exclusively to the Korean market due to KC certification requirements.

சுத்தம் மற்றும் பராமரிப்பு

Cleaning and decontamination of external surfaces

  • Disconnect the power supply cable and the USB cable from the auto-reader. If the device is hot, wait until it has cooled down before handling it.
  • Clean the external surfaces of the device using a microfiber cloth moistened with a solution of mild dishwashing detergent and water. Wring out the cloth so it is damp but not dripping before cleaning, and wipe the outer surfaces of the auto-reader. Then, moisten a clean microfiber cloth with just water only, and repeat the procedure until all traces of detergent are removed from the external surfaces of the device. After cleaning, allow the auto-reader to air dry for at least 1 hour before connecting the power supply cable or the USB cable again.
  • This cleaning procedure can be followed whenever considered appropriate.
  • This cleaning procedure must be followed each time a spill occurs on any of the external surfaces of the auto-reader.
  • If further cleaning is required, or if you have doubts about the cleaning agents you may use, please contact your local distributor.
  • Note: Do not clean the internal parts of the auto-reader.
  • Note: Do not pour liquid onto the device or immerse the it in any liquid. Do not allow any liquid to enter device while it is being cleaned.

பராமரிப்பு

The auto-reader does not require routine maintenance.

உத்தரவாதம்

The products are guaranteed to be free from material and workmanship defects when properly installed, maintained, and used for their intended purpose as indicated in the applicable product label and/or the User Manual. The warranty only applies to the original purchaser.

  • கால
    The warranty period for the Bionova® IC10/20FR Auto-reader is 1 (one) year from the date of installation and may never be extended beyond 5 (five) years from the product’s date of manufacture.
  • பொறுப்பு வரம்பு
    Terragene S.A. shall not be held liable for any loss or damage that results from the unsuitable use of the equipment, negligence the or the user’s full responsibility.
  • தொழில்நுட்ப உதவி
    For information regarding the functioning or condition of the product, contact Terragene S.A. directly at info@terragene.com அல்லது எங்கள் மூலம் webதளம் www.terragene.com. In the USA, please call +1 844 837 7243.

சரிசெய்தல்

  • Refer to the User Manual for detailed troubleshooting measures.
  • பார்வையிடவும் www.terragene.com/IC1020FR or scan the QR code to access the auto-reader User Manual.

Bionova-IC-20FR-Auto-Reader (1)

ஆவணங்கள் / ஆதாரங்கள்

Bionova IC10 20FR Auto Reader [pdf] வழிமுறை கையேடு
IC10 20FR, IC10 20FR Auto Reader, Auto Reader, Reader

குறிப்புகள்

கருத்து தெரிவிக்கவும்

உங்கள் மின்னஞ்சல் முகவரி வெளியிடப்படாது. தேவையான புலங்கள் குறிக்கப்பட்டுள்ளன *