Intel Exiting Boot Agent

விவரக்குறிப்புகள்
- தயாரிப்பு பெயர்: Boot Agent
- வெளியீட்டு தேதி: பிப்ரவரி 2000
- உற்பத்தியாளர்: இன்டெல்
தயாரிப்பு தகவல்
The Boot Agent operates in a client/server environment. In this environment, one or more servers provide remote boot services to a large number of client computers through a common network.
Where to go for more information
ரீட்மீ Files
For more information about installation topics and product errata, see the readme text fileகள். செய்ய view தி files, open the README.TXT file எந்த உரை திருத்தியுடன்.
ஆன்லைன் சேவைகள்
You can use the Internet to download software updates, troubleshooting tips, installation notes, and more. Online services are on the World Wide Web மணிக்கு: http://support.intel.com
This Intel® Boot Agent User’s Guide as well as the software described in it is furnished under license and may only be used or copied in accordance with the terms of the license. The information in this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Intel Corporation. Intel Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this document or any software that may be pro-vided in association with this document. Except as permitted by such license, no part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means without the express written consent of Intel Corporation. Copyright © 2000, Intel Corporation. All rights reserved. Intel Corporation, 5200 N.E. Elam Young Parkway, Hillsboro, OR 97124-6497 Intel Corporation assumes no responsibility for errors or omissions in this document. Nor does Intel make any commitment to update the information contained herein.
- Other product and corporate names may be trademarks of other companies and are used only for explanation and to the owners’ benefit, without intent to infringe.
அறிமுகம்
The Intel Boot Agent is a software product that allows your networked client computer to boot using a program code image supplied by a remote server. The features offered by this product are:
- Compliant with the Wired for Management Baseline 2.0 (WfM 2.0) specification
- Incorporates the software defined in the Pre-boot eXecution Environment (PXE) version 2.0 and 2.1 specifications
- Some versions of the Boot Agent also include support for Remote Program Load (RPL) runtime and loader software (10/100 adapters only)
- Compatible with legacy boot agent environments that use the BOOTP protocol
- Customizable in a pre-execution, stand-alone environment
தயாரிப்பு உள்ளடக்கம்
When you purchase an Intel WfM-compatible adapter, the product package includes the following items related to the Boot Agent:
- A Boot Agent software image integrated into the adapter’s flash ROM device
- A CD-ROM containing a set of DOS utilities, an Intelâ Boot Agent User’s Guide, and a readme file
Intel may occasionally provide Boot Agent software updates. A Boot Agent software update package consists of: - A Boot Agent software image that can be loaded onto your client network adapter’s flash ROM device
- A set of DOS utilities, an Intelâ Boot Agent User’s Guide, and a readme file. This software and documentation as well as updates, are available at the following webதளம்:
- Then, search for “Boot Agent”.
செயல்படும் சூழல்
The Boot Agent operates in a client/server environment. Often, in this environment, one or more servers provide remote boot services to a large number of client computers through a common network.
Boot Services
The Intel® Boot Agent has been tested using the following third-party operating systems/boot services:
- Microsoft* Windows* NT* 4.0 Remote Boot Service
- Microsoft* Windows 2000 Remote Installation Service (RIS)
- Linux* PXE Server
- Novell* NetWare* RPL Module
- IBM* OS/2* RIPL Service
The computer system where the Boot Agent is loaded is considered to be a client with respect to the remote boot capability even if that system acts as a server after the system has finished booting.
Client Computer Hardware Installation
Before you install the Boot Agent, make sure the client computer’s hardware is installed properly—a compatible network adapter is installed and the Boot Agent software image resides within the network adapter’s flash ROM. The following sections guide you through the hardware installation process:
- Set up for a Known Configuration
- Determining the Client Computer Configuration
- Flash ROM and Intel WfM-Compatible Adapters
- Installing Flash ROM Upgrades
Setup for a Known Configuration
If you have an Intel WfM-compatible adapter (such as the Intel® PRO/100+ Management Adapter) installed in your client computer, the flash ROM device is already available in your adapter, and no further installation steps are necessary. However, you may still wish to configure the Boot Agent software. To do so, see “Configuration Setup”. If you do not have an Intel WfM-compatible adapter installed on your client computer, but you know the hardware configuration of your client computer, you can perform the steps indicated in Table 1 and then proceed directly to the proper installation section indicated in the table.
Table 1: Boot Agent Installation Procedures
| Client Computer Hardware Configuration |
Perform These Steps: |
| No network adapter is installed in client computer | 1 Install a compatible network adapter. The adapter documentation gives installation instructions. (Compatible adapters include the Intel® PRO/100+ Management Adapter and the Intel® PRO/100+ Server Adapter. These adapters include an integrated flash ROM device.)
2 If the adapter has an empty flash ROM socket, install a 64 KB (or larger) flash ROM device. See “Installing Flash ROM Upgrades” for installation instructions. |
| A network adapter is installed in cli- ent computer, but no flash ROM device is installed (or the flash ROM is smaller than 64 KB) | 1 Remove the adapter. The adapter documentation gives removal/installation instructions.
2 Install a 64 KB (or larger) flash ROM device containing a Boot Agent software image. See “Installing Flash ROM Upgrades” for installation instructions. 3 Reinstall the adapter. The adapter docu- mentation gives removal/installation instructions. |
| Client computer motherboard incorporates compatible LAN on motherboard (LOM) hardware | 1 Follow the motherboard manufacturer’s update instructions to install the BIOS code that incorporates the Boot Agent software.
2 Alternatively, if the motherboard has a separate ROM socket that accepts a 64 KB (or larger) flash ROM device containing a Boot Agent software image, see “Installing Flash ROM Upgrades” for installation instructions. Contact the motherboard manufacturer to get the code that must be loaded into the flash ROM in this case. |
Identifying the Client Computer Configuration
To determine the hardware configuration of your client computer without removing its cover:
- Examine the back panel of the computer to determine if there is a network adapter already installed. The following figure shows the back panel of a typical computer, and indicates the areas you should examine:

- As shown in the figure, the network connector is an RJ-45 connector. If there is a network connector in the back panel cluster only, it is possible that the computer motherboard incorporates a compatible LAN on the motherboard
(LOM) hardware. Contact the motherboard manufacturer to verify this infor-mation. If your motherboard is equipped with LOM hardware, perform either of the following:- Follow the motherboard manufacturer’s instructions to check if your computer’s BIOS already handles Boot Agent capability. Otherwise, ask your manufacturer for a new BIOS upgrade for your system.
- Alternatively, if the motherboard has a separate ROM socket that accepts a 64 KB (or larger) flash ROM device containing a Boot Agent software image, see “Installing Flash ROM Upgrades” for installation instructions. Contact the motherboard manufacturer to get the code that must be loaded into the flash ROM in this case.
- If there is no network connector at the back of your computer, you must install a network adapter and possibly a flash ROM device on the adapter. Refer to the installation procedures for the adapter for any setup require-ments; then follow the procedures in “Installing Flash ROM Upgrades” before installing the adapter.
- If there is a network connector in one of the add-in board slots, there might be a compatible network adapter already installed in the computer. Perform the following substeps to identify all compatible network adapters already installed in your computer:
- Boot your computer to DOS (a DOS Command Prompt window will not work).
- From the drive or directory containing the Boot Agent software, type fboot and then press Enter.
If there is no flash ROM device installed, you will get the following type of message:

குறிப்பு: If the flash ROM device installed in the adapter ROM socket is not large enough (64 KB or larger), fboot returns a message stating that the flash is too small, and does not allow you to proceed. At this time, (assuming there is a large enough flash device installed), fboot will prompt you to update the flash ROM.
- c Update the flash ROM. See “Installing the Boot Agent Software Image” for instructions.
d If there is no flash device installed, or if the installed flash device is too small, see “Installing Flash ROM Upgrades” for instructions.
Flash ROM and Intel WfM-Compatible Adapters
All Intel Wired-for-Management-compatible (WfM-compatible) adapters are equipped with an integrated flash ROM device. The Boot Agent software image is pre-programmed into the flash ROM device at the factory; therefore, no software installation is required. In some cases, such as when upgrading to a newer software version, you may need to update the flash ROM with a new Boot Agent software image. See “Installing the Boot Agent Software Image” for information about installing or updating the flash ROM with a new Boot Agent software image.
Installing Flash ROM Upgrades
If your adapter is not equipped with an integrated flash ROM device, install a flash ROM device in your adapter.
To install a flash ROM device:
- Turn off and unplug your computer. Then, remove its cover.
- Turn off and unplug the computer before removing the computer cover. Failure to do so could endanger you and might damage the adapter or computer. Observe appropriate static electricity handling precautions when working with components, adapters, and the computer.
- Identify the adapter and the adapter slot in which it is installed. Then, remove the adapter bracket screw.
- Remove the adapter and move it to an area free of static electricity. The following figure shows how to install the flash ROM device in the socket:

- Refer to the figure and install the flash ROM device in the socket of the adapter. Note the location of the notched corner of the flash ROM device and the corresponding notch in the socket. There is only one correct orientation for the flash ROM device.
- Reinstall the adapter in the slot from which you removed it. If you are installing the adapter for the first time, follow the adapter installation instructions and install it in an appropriate PCI expansion slot (refer to the following figure).

- Push the adapter into the slot until it is firmly seated. Then, secure the adapter bracket with a screw.
- கணினி அட்டையை மாற்றி, மின் கம்பியில் செருகவும்.
- Turn on the power. The computer BIOS automatically assigns resources to a PCI adapter. If you get a configuration error, see the troubleshooting instruc-tions in the adapter’s installation guide.
Installing the Boot Agent Software Image
All Intel WfM-compatible adapters, such as the Intel PRO/100+ Management Adapter, have a factory-installed, integrated flash ROM device that has been pre-programmed with a Boot Agent software image. Therefore, no software installation is required. Installation of the Boot Agent on other Intel adapters requires a flash ROM device (non-volatile storage device) to be present within the client computer sys-tem. This flash ROM can take these forms:
- A factory-installed, integrated flash ROM device on the computer motherboard with remote boot enabled, LOM (LAN On Motherboard) hardware support
- A field-upgraded, add-on flash ROM device installed into your network adapter In cases involving hardware upgrades, once a flash ROM device is available within the client computer, a valid Boot Agent software image must be installed onto the flash ROM device. The way in which the Boot Agent software image is installed within the flash ROM depends upon your hardware configuration.
- If your computer includes the network adapter on its motherboard, the Boot Agent software might need to be installed as part of a motherboard BIOS code upgrade. Contact your computer or motherboard manufacturer to upgrade your motherboard BIOS code. Alternatively, it is possible that the motherboard has a ROM socket with a 64 KB (or larger) flash ROM device. In this case, contact the motherboard manufacturer to get the code that must be loaded into the flash ROM.
- If your computer uses a flash ROM-equipped adapter, perform the following steps to install or upgrade the Boot Agent software image:
- The following operation requires the use of a DOS bootable floppy disk containing an executable image of the fboot.exe utility as well as the current flash ROM image file, which will have an .FLS extension. If you do not have fboot.exe on your DOS bootable floppy disk, copy it to your system disk from the CD ROM that came with your product under the \BOOTAGNT directory or acquire the most up-to-date version from Intel’s webதளத்தில்:
http://support.intel.com - Using your DOS bootable floppy disk, boot your computer to a DOS prompt.
- The next several steps require that your computer be booted only to DOS, and not from a Windows “DOS box”. These steps cannot be performed from a DOS Command Prompt window or using a DOS task within Windows.
- குறிப்பு: If the flash ROM device installed in the adapter ROM socket is already programmed (not blank), you may need to take steps to enable your computer to boot from the floppy drive. If necessary, disable the network boot function from either the BIOS Setup program or the Boot Agent’s configuration setup menu. Then reboot to the DOS bootable floppy disk containing the fboot utility that you just prepared.
- வகை:
- fboot
- The following message appears showing a list of all compatible network adapters found in your system, assuming both the adapter and the flash ROM device are properly installed:

- If more than one adapter is installed in your system, you will need to enter the NIC number (from the displayed list) that corresponds to the Ethernet MAC address of the desired adapter. In cases where only one adapter is present, however, press “1” to continue. The next question appears:
Select Option (U)pdate or (R)estore: - Type U (update) if you want the fboot utility to update the flash ROM device with the current version of Boot Agent software. Type R (restore) if you want the fboot utility to write a previously-stored flash image file onto the flash ROM device.
குறிப்பு: As part of the Update operation, fboot creates a backup file on the floppy disk. Make sure that the write-enable tab on the floppy disk is properly set. Prior to the Restore operation, make sure that a flash image file is available in the same directory as the fboot utility. This file will have an automatically-generated filename with an .FLS extension.
If you select the U (update) response, this prompt appears:- Create Restore Image (Y)es or (N)o:
- Type Y (yes) to create a flash image file from the current (not yet updated) image of the flash ROM device. Type N (no) to cause fboot to proceed without first saving a copy of the current contents of the flash ROM device. If you choose not to save a copy of the current contents of the flash ROM device (type N), fboot asks you the following question:
- Continue Update Without Restore Image (Y)es or (N)o:
- Type Y (yes) to continue, which will update the flash image. Type N (no) to cancel the update, which will leave the flash contents unchanged.
குறிப்பு: The fboot utility automatically names the flash image file (backup file) as XXXXXXXX.FLS, where XXXXXXXX are the last eight digits of the adapter’s Ethernet address. If there is already a flash image file in the fboot directory, delete it first if you want to save a new version of the flash ROM device image. The fboot utility will not overwrite this file.
Once you have answered the questions posed by the fboot utility, it creates the flash image file (if appropriate), and then writes the current version of the Boot Agent image to the flash ROM device used by your network adapter. The Boot Agent image is embedded in the fboot utility itself. This process takes approximately one minute and then fboot exits to the DOS prompt.
Server System Setup
குறிப்பு: When the Boot Agent software is installed as an upgrade for an earlier version boot ROM, the associated server-side software may not be compatible with the updated Boot Agent. Contact your system administrator to determine if any server updates are necessary.
For the Boot Agent software to perform its intended job, there must be a server set up on the same network as the client computer. That server must recognize and respond to the PXE or RPL boot protocols that are used by the Boot Agent software. The following sections describe the actions you should take to set up various types of servers to work with the Boot Agent. If you have questions concerning the setup of your server system, contact the manufacturer of your server hardware or your server operating system vendor for assistance. The following sections provide pointers to server setup instructions:
- Windows 2000 RIS Server Setup
- Linux* Server Setup
- Other Server Setup Information
Windows 2000* RIS Server Setup
For information about setting up a Windows 2000 RIS Server:
- பின்வருவனவற்றைக் கலந்தாலோசிக்கவும் web தளம்: http://www.microsoft.com/windows2000
- Select Technical Library.
- Select How it Works.
- Select Remote Operating System Installation under the Management tab.
- Select Download this document.
Linux* Server Setup
- Consult your Linux vendor for information about setting up the Linux Server.
Other Server Setup Information
Various hardware and software manufacturers provide products that support remote boot technology, conforming either to the Wired for Management (WfM) specifications or the PXE/RPL/BOOTP/DHCP protocols. The following web sites provide useful information on setting up your server to such remote boot capabilities:
- http://www.microsoft.com
Microsoft produces operating systems that are used by both client and server systems in a remote boot environment. Search this site for technical informa-tion and commercial products applying to Intel WfM-compatible systems, PXE and RPL environments, and remote booting. - http://www.sco.com
SCO produces SCO* Unix, an operating system used on many servers. Search this site for technical information and commercial products related to remote boot servers. - http://www.bootix.com
Bootix Technology GmbH produces software for boot management solutions. The available products include a large range of special-purpose tools concentrating on LAN and WAN technology for large internal networks. Search this site for remote boot products supporting BOOTP, RPL, and PXE protocols on a range of client and server types. - http://www.weird-solutions.com
Weird Solutions produces client and server support software for Windows NT or Windows 98 computers. Search this site for support software products supporting BOOTP, TFTP, and DHCP services on computers based on Windows NT or Windows 98. - http://www.sun.com
- http://java.sun.com
Sun produces both hardware and software that can be used in either a client or a server application. Search these sites for technical information and com-mercial products applying to WfM-compatible systems, PXE and RPL envi-ronments, and remote booting. - http://samba.org/samba
The Samba organization produces and supports software that runs on UNIX servers and clients. The software available through Samba complies with GNU Public License requirements. Search this site for information on implementing remote booting on UNIX servers. - http://www.novell.com
Novell produces network operating systems and related support software. Search this site for technical information and commercial products applying to WfM-compatible systems, PXE and RPL environments, and remote boot-ing. - http://www.ibm.com
IBM produces both hardware and software that can be used in either a client or a server application. Search this site for technical information and commercial products applying to WfM-compatible systems, PXE and RPL environments, and remote booting. - http://www.altiris.com
Altiris, Inc. produces software for boot management solutions. The available products include special-purpose tools concentrating on LAN and WAN technology for internal networks. Search this site for remote boot products supporting a range of client and server types. - http://www.xpoint-tech.com
Xpoint Technologies, Inc. provides disaster recovery applications that use PXE to restore system configurations from servers. Search this site for information about their products that provide instant recovery for your PC.
கட்டமைப்பு அமைப்பு
The Boot Agent software provides configuration options that allow you to customize the behavior of the Boot Agent software. Changing the Boot Agent configuration will usually be required only the first time you add a new network adapter to a client computer within your network.
Configuring the Boot Agent in a Pre-Boot Environment
You can customize the behavior of the Boot Agent software through a pre-boot (operating system independent) configuration program contained within the adapter’s flash ROM. You can access this pre-boot configuration setup program each time the client computer cycles through the boot process. The boot process is triggered whenever you perform any of the following boot events:
- பவர் ஆன்
- Hard reset (Reset button on system, if available)
- Soft reset (Ctrl+Alt+Del)
- Operating system or application-initiated system restart
When the boot process begins, the screen clears and the computer begins its Power On Self Test (POST) sequence. Shortly after completion of the POST, the Boot Agent software stored in flash ROM executes. The Boot Agent then displays an initialization message, similar to the one below, indicating that the Boot Agent is active.
- Initializing Intel(R) Boot Agent Version 3.X.XX PXE m.m Build nnn (WfM w.w), RPL Vm.mm Press Ctrl+S to enter the Setup Menu.
குறிப்பு: This display may be hidden by the manufacturer’s splash screen. Consult your manufacturer’s documentation for details.
To customize the behavior of the Boot Agent software:
- Press Ctrl+S immediately after the initialization message appears. A configuration setup menu appears, allowing you to set configuration values for the Boot Agent.
குறிப்பு: Immediately after the initialization message appears, and before any subsequent messages appear, you have several seconds in which to press Ctrl+S to display the Boot Agent’s configuration setup menu. If you do not press Ctrl+S, the Boot Agent software will proceed with the boot process, eventually bringing up the operating system. If you miss your opportunity to press Ctrl+S within the allowed number of seconds, reboot the computer to try again. If the setup message is disabled (Show Setup Prompt: Disable), you will not be prompted to press Ctrl+S, even though you can still enter the configuration setup menu using this key combination.
- The configuration setup menu shows a list of configuration settings on the left and their corresponding values on the right. Key descriptions near the bottom of the menu indicate how to change setting values. For each selected setting, a brief “mini-Help” description of its function also appears near the bottom of the menu.
- Select the setting you want to change by pressing Enter to select among settings.
- Once you have accessed the setting you want to change, press the spacebar until the desired value appears.
- If you want to change additional settings, repeat Steps 2 and 3.
- Once you have completed your changes, press F4 to update the adapter with the new values.
Table 2 provides a list of configuration settings, their possible values, and their detailed descriptions.
Table 2: Boot Agent Configuration Settings
| கட்டமைப்பு அமைப்பு |
சாத்தியமான மதிப்புகள் |
விளக்கம் |
| Network Boot Protocol | PXE RPL | Select PXE for use with WfM-compatible network management programs, such as Intel® LANDesk® Management Suite, Windows 2000 RIS, and Linux.
Select RPL for legacy-style remote booting. குறிப்பு: If your Boot Agent does not support RPL, this setting will be unchangeable. |
| துவக்க ஆர்டர் | “Use BIOS Setup Boot Order” | Allows you to select the order in which boot devices are queried when the system boots. If your client computer’s BIOS supports the BIOS Boot Specification (BBS) or allows PnP-compliant selection of the boot order in the BIOS setup program, then this setting will always be “Use BIOS Setup Boot Order” and cannot be changed. In this case, refer to the BIOS setup manual specific to your client computer to set up boot options.
If your client computer does not support BBS- or PnP-compliant BIOS, you can select any one of the values listed in the Possible Values column of this table for this setting except for “Use BIOS Setup Boot Order”. |
| “Try network first, then local drives.” | ||
| “Try local drives first, then network.” | ||
| “Try network only.” | ||
| “Try local drives only.” | ||
| Setup Menu Wait | 2 வினாடிகள் | The number of seconds the Boot Agent |
| நேரம் | 3 வினாடிகள் | waits for you to press Ctrl+S during the |
| 5 வினாடிகள் | system boot process. | |
| 8 வினாடிகள் | ||
| Show Setup Prompt | முடக்கு என்பதை இயக்கு | If you select Enable, the Ctrl+S prompt appears during your computer’s POST sequence.
If you select Disable, the Ctrl+S prompt does not appear. However, you can still press Ctrl+S to enter the setup program during your computer’s POST sequence. |
| கட்டமைப்பு அமைப்பு |
சாத்தியமான மதிப்புகள் |
விளக்கம் |
| Legacy OS Wakeup Support | முடக்கு என்பதை இயக்கு | This setting applies only to Intel PRO/100+ WfM-compatible, 82559- based (or later) adapters.
Select Disable for this setting when using an ACPI Windows operating sys- tem such as Windows 2000 or Windows 98SE. Select Enable to allow non-Windows operating systems (such as DOS or Net- Ware) to make use of the Intel WfM- compatible adapter’s remote wakeup capability. குறிப்பு: Consult your operating system instructions to determine if your operating system supports remote wakeup, as well as how to use this capability. |
Auxiliary DOS Utilities
Intel provides a utility called BROW that provides an alternative means for mod-ifying the adapter configuration settings. BROW is available on Intel’s web தளத்தில்:
- http://support.intel.com
- BROW is also located on the CD-ROM in the directory:
- \BOOTAGNT
BROW Utility
BROW, which stands for Boot ROM / Wake-on-LAN*, is a utility program that changes the default settings of your WfM-compatible adapter. These settings can only be changed with BROW. Once set, these settings cannot be changed from the Boot Agent’s configuration setup menu. BROW can be used to enable or disable the Wake-on-LAN and Boot Agent capabilities, as well as enable or disable some settings used by the Boot Agent. If you disable Wake-on-LAN on an adapter, that adapter is unable to respond to a wake-up packet and remotely power on the computer. Disabling Wake-on-LAN also reduces the amount of current the adapter draws from the standby power supply when the computer is powered off. Disabling the Boot Agent prevents it from executing during the computer power up/boot sequence.
Running BROW
BROW must be run with the computer booted to DOS only, with no software drivers loaded. This utility cannot be run in a DOS window in any Microsoft Windows product or in DOS compatibility mode in IBM OS/2. BROW can be run with any of the command line options found in Table 3 using the following syntax:
- BROW [-option]…
Table 3: BROW Options
|
விருப்பம் |
குறுகிய வடிவம் |
விளக்கம் |
| -ALL | Selects all adapters found in system. | |
| -EXITCODES | Brings up exit code help. | |
| -HELP | -? | Brings up command line help. |
| -NIC=XX | Selects a specific adapter (1-8).
BROW will not interact with any adapters unless you explicitly specify which adapters you wish it to interact with. You can use the -NIC-xx option to select a single adapter, or use the -ALL option to select all of the adapters in your system. |
|
| -BOOTENABLE | -இரு | Enables Boot ROM. |
| -BOOTDISABLE | -பி.டி | Disables Boot ROM. |
| -WOLDISABLE | -WOLD | Disables remote system wake up (WOL). |
| -WOLENABLE | -WOLE | Enables remote system wake up (WOL). |
குறிப்பு: If you run BROW without any command line options, the utility will display a list of all the adapters found in your system.
Exampலெ 1
To disable WOL on all adapters, call BROW like this: BROW -ALL -WOLDISABLE
Exampலெ 2
To enable WOL on the second adapter found in your system, call BROW like this: BROW -NIC=2 -WOLENABLE
Exampலெ 3
To disable the Boot ROM on all adapters, call BROW like this: BROW -ALL -BOOTDISABLE
Exampலெ 4
To enable the Boot ROM on the first adapter found in your system, call BROW like this: BROW -NIC=1 -BOOTENABLE
Boot Agent Messages
The Boot Agent may display one or more of the following messages during initialization:
Information Messages
This option has been locked and cannot be changed. This message appears when the user tries to change a configuration setting that has been locked by your system administrator with the BROW utility. If you think you should be able to change the configuration setting, consult your system administrator. Adapter-Related Error Messages
PXE-E05: The LAN adapter’s configuration is corrupted or has not been initialized. The Boot Agent cannot continue.
The Boot Agent determined that the adapter EEPROM checksum is incorrect. The agent will return control to the BIOS and not attempt to remote boot. Try to update the flash image. If this does not solve the problem, contact your system administrator or Intel® Customer Support either by telephone or over the World Wide Web. Phone numbers and web sites are listed at the back of this manual.
PXE-E04: The LAN adapter is not functioning correctly or the wrong Boot Agent is installed. The Boot Agent cannot continue.
The Boot Agent was unable to read one or more of the adapter’s PCI configuration registers. The adapter may be misconfigured, or the wrong Boot Agent image may be installed on the adapter. The Boot Agent will return controlto the BIOS and not attempt to remote boot. Try to update the flash image. If this does not solve the problem, contact your system administrator or Intel® Customer Support either by telephone or over the World Wide Web. Phone numbers and web sites are listed at the back of this manual.
System-Level Error Messages
PXE-E06: This system does not support PCI option ROMs. The Boot Agent cannot continue.
The BIOS does not support the mapping of the PCI expansion ROMs into upper memory as required by the PXE specification. The Boot Agent cannot function in this system. The Boot Agent returns control to the BIOS and does not attempt to remote boot. You may be able to resolve the problem by updating the BIOS on your system. If updating your system’s BIOS does not fix the problem, contact your system administrator or your computer vendor’s customer support to resolve the problem.
PXE-E00: This system does not have enough free conventional memory. The Boot Agent cannot continue. The Boot Agent was unable to find enough free base memory (below 640 K) to install the PXE client software. The system cannot boot via PXE in its current configuration. The error returns control to the BIOS, and the system does not attempt to remote boot. If this error persists, try updating your system’s BIOS to the most-recent version. Contact your system administrator or your computer vendor’s customer support to resolve the problem.
சிக்கலைத் தீர்க்கும் நடைமுறைகள்
The following list of problems and associated solutions covers a representative set of problems that you might encounter while using the Boot Agent. If you are experiencing a problem that is not listed in this section, contact Intel® Customer Support either by telephone or over the World Wide Web. Phone numbers and web sites are listed at the back of this manual.
Media test failure, check cable
When an error message like this appears, it means the adapter did not detect a viable network connection. Look at the RJ-45 network connector at the back of your computer and verify that a network cable is plugged in. See “Identifying the Client Computer Configuration” for help in identifying the network connector. If the network cable is installed correctly at the rear of your computer, it is possible that it is not connected to a server, or that the server has not yet been set up correctly. Make sure your computer is properly set up and connected to the network server before trying to set up the Boot Agent.
Flash device wrong size
The full version of Boot Agent software cannot be loaded into a flash ROM device smaller than 64 KB. If a 32 KB (or smaller) flash ROM device is detected in the adapter, the Boot Agent software returns the “Flash device wrong size” message. Assuming the device is socketed, remove the “too small” device and install a blank 64 KB (or larger) flash ROM device. See “Configuration Setup” for more information.
Cannot change boot order
If you are accustomed to redefining your computer’s boot order using the motherboard BIOS setup program, the default settings of the Boot Agent setup program can override that setup. To change the boot sequence, you must first override the Boot Agent setup program defaults. To start the Boot Agent configuration setup program, press Ctrl+S during the time the initialization message appears. A configuration setup menu appears, allowing you to set configuration values for the Boot Agent. If you do not press Ctrl+S, the Boot Agent software proceeds with the boot process, eventually bringing up the operating system. To change your computer’s boot order setting, see “Configuration Setup”.
There are configuration/operation problems with the boot process
For some specific configurations and operating conditions, the boot process does not proceed as expected. Contact Intel® Customer Support.
Not getting a prompt to go to Boot Agent setup program
This is actually a feature of the Boot Agent product. As part of the setup program, one of the options allows you to turn off the prompt that says:
- Press Ctrl+S to enter the Setup Menu.
You can still press the Ctrl+S key combination to enter the setup program, but the prompt is not displayed telling you when to do so. Immediately after POST, repeatedly press the Ctrl+S key combination until the Boot Agent setup program starts. While in the setup program, you can restore the prompt message if you want.
My computer does not complete POST
This problem occurs before the Boot Agent software has even begun operating. There is a software or BIOS problem with your computer. Contact your computer manufacturer’s customer support group for help in correcting your problem.
After booting, my computer experiences problems
After the Boot Agent product has finished its sole task (remote booting), it no longer has any effect on the client computer’s operation. Any problems you are having with your computer after it completes the boot process are most likely related to another part of the computer. If you are having problems with the local (client) or network operating system, contact the operating system manufacturer for assistance. If you are having problems with an application program, contact the application manufacturer for assistance. If you are having problems with any of your computer’s hardware or with the BIOS, contact your computer system manufacturer for assistance.
சொற்களஞ்சியம்
- The Glossary defines terms, abbreviations, and acronyms that apply directly to the Boot Agent.
- BBS BIOS Boot Specification
- BIOS Basic Input Output System
- BIS Boot Integrity Services
- BOOTP Bootstrap Protocol
- DHCP டைனமிக் ஹோஸ்ட் உள்ளமைவு நெறிமுறை
- ESD Electro-Static Discharge
- NIC Network Interface Controller (same as adapter)
- OS இயக்க முறைமை
- PnP Plug and Play
- PXE Pre-boot eXecution Environment
- RPL Remote Program Load
- URL சீரான வள இருப்பிடம்
- WfM Wired for Management
Licensing and Support
Network Software License Agreement
முக்கியமானது - நகலெடுப்பதற்கு முன், நிறுவுதல் அல்லது பயன்படுத்துவதற்கு முன் படிக்கவும்.
பின்வரும் விதிமுறைகள் மற்றும் நிபந்தனைகளை நீங்கள் கவனமாகப் படிக்கும் வரை, இந்த மென்பொருளையும் அதனுடன் தொடர்புடைய பொருட்களையும் (ஒட்டுமொத்தமாக, "மென்பொருள்") பயன்படுத்தவோ ஏற்றவோ வேண்டாம். மென்பொருளை ஏற்றுவதன் மூலம் அல்லது பயன்படுத்துவதன் மூலம், இந்த ஒப்பந்தத்தின் விதிமுறைகளை ஏற்கிறீர்கள். நீங்கள் ஒப்புக்கொள்ள விரும்பவில்லை என்றால், மென்பொருளை நிறுவவோ பயன்படுத்தவோ வேண்டாம்.
உரிமம்.
You may copy the Software onto a single computer for your personal, non-commercial use, and you may make one back-up copy of the Software, subject to these conditions:
- This Software is licensed for use only in conjunction with Intel component products. Use of the Software in conjunction with non-Intel component products is not licensed hereunder.
- You may not copy, modify, rent, sell, distribute or transfer any part of the Software except as provided in this Agreement, and you agree to prevent unauthorized copying of the Software.
- You may not reverse engineer, decompile, or disassemble the Software.
- You may not sublicense or permit simultaneous use of the Software by more than one user.
- The Software may contain the software or other property of third party suppliers, some of which may be identified in, and licensed in accordance with, any enclosed “license.txt” file அல்லது பிற உரை அல்லது file.
OWNERSHIP OF SOFTWARE AND COPYRIGHTS
மென்பொருளின் அனைத்து நகல்களுக்கான தலைப்பு இன்டெல் அல்லது அதன் சப்ளையர்களிடம் உள்ளது. மென்பொருளானது அமெரிக்கா மற்றும் பிற நாடுகளின் சட்டங்கள் மற்றும் சர்வதேச ஒப்பந்த விதிகளால் பதிப்புரிமை மற்றும் பாதுகாக்கப்படுகிறது. மென்பொருளிலிருந்து எந்த பதிப்புரிமை அறிவிப்புகளையும் நீங்கள் அகற்றக்கூடாது. இன்டெல் எந்த நேரத்திலும் மென்பொருளில் மாற்றங்களைச் செய்யலாம் அல்லது அதில் குறிப்பிடப்பட்டுள்ள உருப்படிகளில் எந்த முன்னறிவிப்பும் இல்லாமல், ஆனால் மென்பொருளை ஆதரிக்கவோ புதுப்பிக்கவோ கடமைப்பட்டிருக்காது. வெளிப்படையாக வழங்கப்பட்டதைத் தவிர, இன்டெல் காப்புரிமைகள், பதிப்புரிமைகள், வர்த்தக முத்திரைகள் அல்லது பிற அறிவுசார் சொத்துரிமைகளின் கீழ் வெளிப்படையான அல்லது மறைமுகமான உரிமையை இன்டெல் வழங்காது. பெறுநர் இந்த விதிமுறைகளுக்கு முழுமையாகக் கட்டுப்படுவதை ஒப்புக்கொண்டால் மற்றும் மென்பொருளின் நகல்களை நீங்கள் வைத்திருக்கவில்லை என்றால் மட்டுமே நீங்கள் மென்பொருளை மாற்றலாம்.
LIMITED MEDIA WARRANTY
If the Software has been delivered by Intel on physical media, Intel warrants the media to be free from material physical defects for a period of ninety (90) days after delivery by Intel. If such a defect is found, return the media to Intel for replacement or alternate delivery of the Software as Intel may select.
மற்ற உத்தரவாதங்களின் விலக்கு
EXCEPT AS PROVIDED ABOVE, THE SOFTWARE IS PROVIDED “AS IS” WITHOUT ANY EXPRESS OR IMPLIED WARRANTY OF ANY KIND, INCLUDING WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT, OR FITNESS FOR A PARTICULAR PURPOSE. Intel does not warrant or assume responsibility for the accuracy or completeness of any information, text, graphics, links or other items contained within the Software. LIMITATION OF LIABILITY. IN NO EVENT SHALL INTEL OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, LOST PROFITS, BUSINESS INTERRUPTION, OR LOST INFORMATION) ARISING OUT OF THE USE OF OR INABILITY TO USE THE SOFTWARE, EVEN IF INTEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME JURISDICTIONS PROHIBIT EXCLUSION OR LIMITATION OF LIABILITY FOR IMPLIED WARRANTIES OR CONSEQUENTIAL OR INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. YOU MAY ALSO HAVE OTHER LEGAL RIGHTS THAT VARY FROM JURISDICTION TO JURISDICTION. TERMINATION OF THIS AGREEMENT. Intel may terminate this Agreement at any time if you violate its terms. Upon termination, you will immediately destroy the Software or return all copies of the Software to Intel.
Year 2000 Statement
An Intel product, when used in accordance with its associated documentation, is “Year 2000 Capable” when, upon installation, it accurately stores, displays, processes, provides, and/or receives date data from, into, and between the twentieth and twenty-first centuries, including leap year calculations, pro-vided that all other technology used in combination with said product properly exchanges date data with it. See http://www.intel.com/support/year2000 மேலும் தகவலுக்கு.
Intel® Automated Customer Support
You can reach Intel’s automated support services 24 hours a day, every day at no charge. The services contain the most up-to-date information about Intel products. You can access installation instructions, troubleshooting information, and general product information.
Web and Internet Sites
- ஆதரவு: http://support.intel.com
- Network Products: http://www.intel.com/network
- கார்ப்பரேட்: http://www.intel.com
- FTP Host: download.intel.com
- FTP Directory:/support/etherexpress/
Customer Support Technicians
அமெரிக்கா மற்றும் கனடா: 1-916-377-7000 (7:00 – 17:00 M-F Pacific Time) Worldwide access: Intel has technical support centers worldwide. Many of the centers are staffed by technicians who speak the local languages. For a list of all Intel support centers, the telephone numbers, and the times they are open, download document 9089 from one of the automated services.
அடிக்கடி கேட்கப்படும் கேள்விகள்
Where can I find more information about installation topics and product errata?
You can refer to the readme text files for detailed information about installation topics and product errata. Open the README.TXT file with any text editor to view இவை files.
ஆவணங்கள் / ஆதாரங்கள்
![]() |
intel Exiting Intel Boot Agent [pdf] பயனர் வழிகாட்டி Exiting Intel Boot Agent, Intel Boot Agent, Boot Agent |

